MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/medsci14020229

Медицинская библиотека · Medical sciences (Basel, Switzerland) · 2026

Radiologic-Pathologic Discordance After Image-Guided Breast Biopsy: A Systematic Review of Prevalence and Outcomes.

Yincharoen Pirada, Sharma Crystal Pravina, Tawanwongsri Weeratian

СтатьяСистематический обзорПеревод в очереди

Аннотация

BACKGROUND

Radiologic-pathologic discordance remains an important concern owing to the absence of standardized guidelines. This systematic review aimed to summarize the prevalence of discordant benign outcomes, defined as suspicious imaging findings with benign biopsy histology insufficient to explain the imaging abnormality, and to quantify malignancy upgrades subsequent to additional tissue assessment.

METHODS

This review was conducted in accordance with PRISMA 2020 guidelines and was prospectively registered. Eligible studies reported primary patient-level or aggregated data on radiologic-pathologic correlations post-image-guided breast biopsy and provided extractable data on discordant benign prevalence and/or subsequent malignancy upgrades.

RESULTS

Twenty-three studies were included. Lesion-/biopsy-based cohorts focused on biopsied abnormalities for analysis. Twelve studies directly estimated discordant-benign prevalence, whereas 11 studies did not, as study designs were discrepant-only, lesion-defined, or excision-restricted. Unselected cohorts with a cohort-wide correlation reported 1.2-5.3% discordant benign prevalence for all biopsies. When restricted to excised lesions, the discordant benign ascertainment rate was 7.4%, representing an excision-ascertained subset rather than the cohort-wide prevalence. Using benign-biopsy denominators, the discordance rate was 1.5-19.2%. Malignancy upgrades among discordant benign lesions ranged from 0 to 100% in selected subsets; however, several clinically relevant cohorts reported representative rates of approximately 20-40%, with some high-risk cohorts exceeding 50%.

CONCLUSIONS

Discordant benign biopsy results are rare in unselected biopsy populations but carry a clinically meaningful upgrade risk, which warrants structured radiologic-pathologic correlation and prompt diagnostic resolution through repeat sampling or excision. Improvements in comparability and management algorithms require standardized definitions, uniform denominators aligned with all biopsied lesions, and prospective multicenter designs.

Для цитирования: Yincharoen Pirada, Sharma Crystal Pravina, Tawanwongsri Weeratian. Radiologic-Pathologic Discordance After Image-Guided Breast Biopsy: A Systematic Review of Prevalence and Outcomes.. Medical sciences (Basel, Switzerland). 2026. DOI: 10.3390/medsci14020229.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.