MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41370-024-00681-y

Медицинская библиотека · Journal of exposure science & environmental epidemiology · 2024

The application of PTR-MS and non-targeted analysis to characterize VOCs emitted from a plastic recycling facility fire.

Vitucci Eva C M, Oladeji Oladayo, Presto Albert A, Cannon Carolyn L, Johnson Natalie M

СтатьяПеревод в очереди

Аннотация

BACKGROUND

On April 11th, 2023, the My Way Trading (MWT) recycling facility in Richmond, Indiana caught fire, mandating the evacuation of local residents and necessitating the U.S. Environmental Protection Agency (EPA) to conduct air monitoring. The EPA detected elevated levels of plastic combustion-related air pollutants, including hydrogen cyanide and benzene.

OBJECTIVE

We aimed to identify these and other volatile organic compounds (VOCs) present as well as to identify the potential hazard of each compound for various human health effects.

METHODS

To identify the VOCs, we conducted air monitoring at sites within and bordering the evacuation zone using proton transfer reaction mass spectrometry (PTR-MS) and non-targeted analysis (NTA). To facilitate risk assessment of the emitted VOCs, we used the EPA Hazard Comparison Dashboard.

RESULTS

We identified 46 VOCs, within and outside the evacuation zone, with average detection levels above local background levels measured in Middletown, OH. Levels of hydrogen cyanide and 4 other VOCs were at least 1.8-fold higher near the incidence site in comparison to background levels and displayed unique temporal and spatial patterns. The 46 VOCs identified had the highest hazardous potential for eye and skin irritation, with approximately 45% and 39%, respectively, of the VOCs classified as high and very high hazards for these endpoints. Notably, all detected VOC levels were below the hazard thresholds set for single VOC exposures; however, hazard thresholds for exposure to VOC mixtures are currently unclear.

IMPACT: This study serves as a proof-of-concept that PTR-MS coupled with NTA can facilitate rapid identification and hazard assessment of VOCs emitted following anthropogenic disasters. Furthermore, it demonstrates that this approach may augment future disaster responses to quantify additional VOCs present in complex combustion mixtures.

Для цитирования: Vitucci Eva C M, Oladeji Oladayo, Presto Albert A, Cannon Carolyn L, Johnson Natalie M. The application of PTR-MS and non-targeted analysis to characterize VOCs emitted from a plastic recycling facility fire.. Journal of exposure science & environmental epidemiology. 2024. DOI: 10.1038/s41370-024-00681-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.