MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.scitotenv.2018.10.365

Медицинская библиотека · The Science of the total environment · 2018

Intrusion of chlorinated hydrocarbons and their degradation products from contaminated soil. Measurement of indoor air quality and biomonitoring by analysis of end-exhaled air.

Scheepers Paul T J, Graumans Martien H F, van Dael Maurice, de Werdt Laurie, Pinckaers Nicole, Beckmann Gwendolyn, Anzion Rob

СтатьяПеревод в очереди

Аннотация

A historic soil contamination of chlorinated hydrocarbons from a former dry cleaning shop caused intrusion of vapors into a building currently used as bookshop. The aim of this study was to determine the indoor air quality and the uptake of soil contaminants and their degradation products. Samples of indoor air were collected over one week in the warm and one week in the cold season. Pre-shift and post-shift samples of end-exhaled air were collected from two employees. Chlorinated hydrocarbons were analyzed in indoor air and exhaled air samples using thermal desorption gas chromatography mass spectrometry (TD-GC-MS). Tetrachloroethylene (PER), and its degradation products trichloroethylene (TRI), 1,1-dichloroethylene (1,1-DCE), 1,2-cis-dichloroethylene (1,2-cis-DCE), 1,2-trans-dichloroethylene (1,2-trans-DCE), methylene chloride (MC) and vinyl chloride (VC) were determined in ambient air. PER was the prime contaminant with a week average (±sd) of 805.2 ± 598.6 μg/m3 in June 2016 and 1031 ± 499.3 μg/m3 in December 2017. MC, 1,2-cis-DCE and TRI were detected at concentrations below 2.3 μg/m3. 1,1-DCE and VC were not detected. In exhaled air PER, 1,1-DCE, and MC were detected in both June and December, whereas TRI, 1,2-cis-DCE and 1,2-trans-DCE were only detected on one or two days in the cold season. VC was not detected in exhaled air. For PER, the mean concentrations (±sd) in end-exhaled air increased from a five days (Mon-Fri) average pre-shift value of 22.2 ± 8.0 to a post-shift value of 52.6 ± 15.5 ng/L in the male shop owner (p < 0.01) and in the female cashier these values were 26.0 ± 3.6 and 63.6 ± 12.7 ng/L, respectively (p < 0.01). Intrusion of chlorinated soil contaminants resulted in contamination of indoor air above the current accepted indoor air level for PER of 250 μg/m3. For PER in end-exhaled air an accumulation over the workweek was not observed.

Для цитирования: Scheepers Paul T J, Graumans Martien H F, van Dael Maurice, de Werdt Laurie, Pinckaers Nicole, Beckmann Gwendolyn, Anzion Rob. Intrusion of chlorinated hydrocarbons and their degradation products from contaminated soil. Measurement of indoor air quality and biomonitoring by analysis of end-exhaled air.. The Science of the total environment. 2018. DOI: 10.1016/j.scitotenv.2018.10.365.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.