MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.aca.2025.345021

Медицинская библиотека · Analytica chimica acta · 2025

A highly sensitive multicolor quantum dots-polylysine@FLISA platform for the simultaneous detection of serum PD-L1, SORL1, and GDF-15 levels.

Chen Tongfang, Liang Jingjie, Liu Weiqing, Luo Xiaorong, Zhou Fengxia, Zhou Yingchun, Xing Shan

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Colorectal cancer (CRC) requires accurate diagnostic approaches for effective clinical management. Serum biomarkers PD-L1, SORL1, and GDF-15 offer valuable diagnostic information, but their simultaneous detection is hindered by the limited sensitivity and multiplexing capacity of conventional immunoassays. This work addresses the critical need for a highly sensitive multiplexed platform for precise CRC diagnosis.

RESULTS

We constructed a multicolor QDs-K@FLISA platform employing K24 polylysine-conjugated CdTe quantum dots with distinct emissions (543/587/647 nm). The K-peptide enabled multi-QD loading, significantly amplifying fluorescence signals and facilitating ultrasensitive triplex detection. The assay achieved exceptional sensitivity with detection limits of 0.996 pg/mL (PD-L1), 1.101 pg/mL (SORL1), and 1.035 pg/mL (GDF-15), along with wide linear ranges (7.8-500 pg/mL for PD-L1/SORL1; 6-1600 pg/mL for GDF-15). High reproducibility was demonstrated (RSD <2.3 %). Clinical validation using 120 serum samples revealed strong correlation with reference methods (R2 > 0.99) and effective discrimination between CRC patients and healthy controls.

SIGNIFICANCE AND NOVELTY: This work establishes a novel peptide-mediated multi-QD loading strategy that enables ultrasensitive multiplexed detection of CRC biomarkers. The platform presents significant potential for clinical applications in CRC diagnosis and biomarker profiling.

Для цитирования: Chen Tongfang, Liang Jingjie, Liu Weiqing, Luo Xiaorong, Zhou Fengxia, Zhou Yingchun, Xing Shan. A highly sensitive multicolor quantum dots-polylysine@FLISA platform for the simultaneous detection of serum PD-L1, SORL1, and GDF-15 levels.. Analytica chimica acta. 2025. DOI: 10.1016/j.aca.2025.345021.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.