European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2019
Auricular prostheses attached to osseointegrated implants: multidisciplinary work-up and clinical evaluation.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Vijverberg Maarten A, Verhamme Luc, van de Pol Pascal, Kunst Henricus P M, Mylanus Emmanuel A M, Hol Myrthe K S
Аннотация
PURPOSE: Not long after the introduction of osseointegrated implants outside the oral cavity, auricular prostheses are retrained on osseointegrated implants. New insights have been gained with the next-generation percutaneous osseointegrated titanium implants for bone conduction hearing since its introduction in 2010. As a result, the same technology was introduced in the Vistafix® system (VXI implant) to retain auricular prostheses. The aim of this study is to evaluate the surgical procedure, clinical outcome, and satisfaction of the patient of osseointegration-retained auricular prosthesis using VXI implants.
MATERIALS AND METHODS: 11 patients who received an auricular prosthesis using VXI implants between December 2012 and November 2017 were evaluated retrospectively. The patient's medical files were reviewed to assess clinical complications and the necessity for revision surgery. The subjective outcome was measured using the Glasgow benefit inventory (GBI).
RESULTS: In total, 31 implants were placed in 11 patients. None of these implants were lost nor revision surgery needed. An adverse skin reaction was observed in 13.0% of the implants and in 27.2% of the patients, adequately treated with an antibiotic ointment. The average follow-up time was 2 years and 7 months. The GBI displayed a positive score in every patient.
CONCLUSIONS: The VXI implants used are a safe and reliable treatment option for retaining auricular prostheses in patients with an absent auricle. Patients were satisfied with their auricular prosthesis and showed benefit in quality of life. Studies with larger numbers and preferably a prospective character are needed to draw statistically significant conclusions.
MATERIALS AND METHODS: 11 patients who received an auricular prosthesis using VXI implants between December 2012 and November 2017 were evaluated retrospectively. The patient's medical files were reviewed to assess clinical complications and the necessity for revision surgery. The subjective outcome was measured using the Glasgow benefit inventory (GBI).
RESULTS: In total, 31 implants were placed in 11 patients. None of these implants were lost nor revision surgery needed. An adverse skin reaction was observed in 13.0% of the implants and in 27.2% of the patients, adequately treated with an antibiotic ointment. The average follow-up time was 2 years and 7 months. The GBI displayed a positive score in every patient.
CONCLUSIONS: The VXI implants used are a safe and reliable treatment option for retaining auricular prostheses in patients with an absent auricle. Patients were satisfied with their auricular prosthesis and showed benefit in quality of life. Studies with larger numbers and preferably a prospective character are needed to draw statistically significant conclusions.
Предметные рубрики MeSH
AdultAgedBone ConductionBone-Anchored ProsthesisCongenital MicrotiaEar AuricleEar Deformities, AcquiredFemaleHumansMaleMiddle AgedNetherlandsOsseointegrationOutcome and Process Assessment, Health CarePostoperative ComplicationsProspective StudiesProstheses and ImplantsProsthesis DesignProsthesis ImplantationQuality of LifeReoperationRetrospective StudiesTitanium