IMPORTANCE

Orbital floor fractures are commonly seen in clinical practice, yet the etiology underlying the mechanism of fracture is not well understood. Current research focuses on the buckling theory and hydraulic theory, which implicate trauma to the orbital rim and the globe, respectively.

OBJECTIVE

To elucidate and define the biomechanical factors involved in an orbital floor fracture.

DESIGN, SETTING, AND

PARTICIPANTS

A total of 10 orbits from 5 heads (3 male and 2 female) were used for this study. These came from fresh, unfixed human postmortem cadavers that were each selected so that the cause of death did not interfere with the integrity of orbital walls. Using a drop tower with an accelerometer, we measured impact force on the globe and rim of cadaver heads affixed with strain gauges.

RESULTS

The mean impacts for rim and globe trauma were 3.9 J (95% CI, 3.4-4.3 J) and 3.9 J (95% CI, 3.5-4.3 J), respectively. Despite similar impact forces to the globe and rim, strain-gauge data displayed greater mean strain for globe impact (6563 μS) compared with rim impact (3530 μS); however, these data were not statistically significant (95% CI, 3598-8953 μS; P = .94).

CONCLUSIONS AND RELEVANCE: Our results suggest that trauma directly to the globe predisposes a patient to a more posterior fracture while trauma to the rim demonstrates an anterior predilection. Both the hydraulic and buckling mechanisms of fracture exist and demonstrate similar fracture thresholds.

LEVEL OF EVIDENCE: NA.

Для цитирования: Patel Sagar, Andrecovich Christopher, Silverman Michael, Zhang Liying, Shkoukani Mahdii. Biomechanic Factors Associated With Orbital Floor Fractures.. JAMA facial plastic surgery. 2017. DOI: 10.1001/jamafacial.2016.2153.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.