DOI 10.1016/j.jvscit.2025.101741
Cadaveric training model for the management of type B aortic dissection using thoracic endovascular aortic repair along with the PETTICOAT technique.
Аннотация
This model gives residents and fellows practice in the surgical repair of a type B aortic dissection using thoracic endovascular aortic repair implantation by the Provisional Extension To Induce Complete Attachment (PETTICOAT) technique. A human cadaveric model was created to simulate the procedure. A Dacron graft was pulled into the aorta distal to the left subclavian artery using two glidewires. Imaging confirmed the creation of a second lumen by the graft positioned within the aorta to simulate an aortic dissection. The PETTICOAT technique was then implemented with the implantation of a Cook Dissection stent. This proved the method to be a reproducible means to train residents and fellows in type B aortic dissection repair using the PETTICOAT technique.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.