MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/j.jcrs.0000000000001592

Медицинская библиотека · Journal of cataract and refractive surgery · 2025

Improving the accuracy of lens formulas for in-the-bag intraocular lens implantation in Marfan syndrome patients with ectopia lentis.

Shen Xin, Chen Zexu, Jia Wannan, Wang Yalei, Chen Xinyao, Chen Tianhui, Liu Yan, Song Linghao, Huo Qiuyi, Jiang Yongxiang

СтатьяПеревод в очереди

Аннотация

PURPOSE: To improve the accuracy of intraocular lens (IOL) power calculation formulas by modifying the effective lens position (ELP) equations for patients with Marfan syndrome (MFS) and ectopia lentis (EL) undergoing in-the-bag IOL implantation.

SETTING

Eye and ENT Hospital of Fudan University, Shanghai, China.

DESIGN

Retrospective cohort study.

METHODS

The formula-specific ELP was obtained from the SRK/T, T2, Holladay 1, and HofferQ formulas. The back-calculated ELP was obtained based on the vergence formula using preoperative biometry, postoperative refraction, and IOL power. The generalized linear models (GLMs) or gradient boosting machines were used to predict ELP or ELP error.

RESULTS

255 patients (255 eyes) were assigned randomly into a training set and a validation set (7:3 ratio). Linear correlation identified axial length (AL), corneal height, and white-to-white distance as predictors of ELP and ELP error for patients with shorter AL (AL ≤24 mm). For those with longer AL (AL >24 mm), AL and the central corneal radius were identified as the primary predictors. Incorporating these predictors into the modified ELP formula significantly improved the accuracy in the validation set, including SRK/T, T2, Haigis, Holladay 1, and HofferQ formulas. The improvement was more pronounced in patients with shorter AL. In addition, the GLM-modified formulas outperformed both the Barrett Universal II and Kane formulas. The accuracy across different ocular dimensions was comparable among the modified formulas, based on which an online calculator was developed.

CONCLUSIONS

Using the more accurately predicted ELP can significantly improve the accuracy of existing formulas in patients with MFS.

Для цитирования: Shen Xin, Chen Zexu, Jia Wannan, Wang Yalei, Chen Xinyao, Chen Tianhui, Liu Yan, Song Linghao, Huo Qiuyi, Jiang Yongxiang. Improving the accuracy of lens formulas for in-the-bag intraocular lens implantation in Marfan syndrome patients with ectopia lentis.. Journal of cataract and refractive surgery. 2025. DOI: 10.1097/j.jcrs.0000000000001592.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.