MedElevator Войти в исследования
← Поиск публикаций

DOI 10.52054/fvvo.14.2.025

Медицинская библиотека · Facts, views & vision in ObGyn · 2022

3D transvaginal ultrasound diagnosis of uterine septa according to different classifications: are there other measurements that correlate to reproductive outcome in small indentation length?

Russo C, Conway F, Siciliano T, Selntigia A, Giuseppe Martire F, Soreca G, Ticconi C, Exacoustos C

СтатьяПеревод в очереди

Аннотация

BACKGROUND

High discrepancy between current classifications was observed in the definition of uterine septa, especially for indentation lengths >5 <10mm.

OBJECTIVES

To assess the discrepancy between current classifications in the diagnoses of septate uterus and to correlate them with reproductive outcomes; to detect 3D transvaginal ultrasound (TVS) additional measurements, which can better correlate small indentation lengths >5 <10mm to reproductive failures.

MATERIALS AND

METHODS

Observational study enrolling 664 women of reproductive age with 3D ultrasound diagnosis of an indentation length ≥3mm. For each patient a detailed reproductive history was taken before performing 3D transvaginal examination. Patients with previous uterine surgery or metroplasty were excluded.

MAIN OUTCOME MEASURES: Indentation lengths >5 <10mm showed high discrepancy in the diagnosis of uterine septum between different classifications. For these small indentations additional 3D measurements (indentation angle, septal width and septal length/ fundal myometrial thickness (L/M) ratio) were correlated to infertility and recurrent miscarriage.

RESULTS

Among the cohort, 215 patients showed an indentation length >5 <10mm; 136 tried to conceive: 69 (51%) were infertile, 38 (28%) had recurrent miscarriages (≥2) and 5 (4%) had at least one delivery. Recurrent miscarriage significantly correlated to an indentation angle >134°; whereas infertility to an indentation width <32mm and a L/M ratio >75%.

CONCLUSIONS

Wide discrepancies between different classifications are more evident in indentation lengths >5 <10mm. Additional measurements on 3D coronal section may help to evaluate the risk of infertility or recurrent miscarriage.

WHAT IS NEW?: Additional 3D TVS measurements, beyond septal lengths, in particular for small fundal indentation, may help in predicting the risk of developing adverse reproductive outcomes.

Для цитирования: Russo C, Conway F, Siciliano T, Selntigia A, Giuseppe Martire F, Soreca G, Ticconi C, Exacoustos C. 3D transvaginal ultrasound diagnosis of uterine septa according to different classifications: are there other measurements that correlate to reproductive outcome in small indentation length?. Facts, views & vision in ObGyn. 2022. DOI: 10.52054/fvvo.14.2.025.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.