MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/eja.0000000000001424

Медицинская библиотека · European journal of anaesthesiology · 2021

Generic versus reference listed ropivacaine for peripheral nerve blockade: A randomised, triple-blinded, crossover, equivalence study in volunteers.

Opfermann Philipp, Marhofer Peter, Hopkins Philip M, Columb Malachy O, Zadrazil Markus, Stimpfl Thomas, Marhofer Melanie, Zeitlinger Markus

СтатьяРандомизированное исследованиеEquivalence TrialПеревод в очереди

Аннотация

BACKGROUND

Generic drug preparations do not require the same degree of scrutiny as the originally licensed preparation before they can be approved for clinical use. The permitted tolerance limits for bioequivalent preparations might be associated with clinically relevant differences for drugs with a narrow therapeutic index, such as local anaesthetics.

OBJECTIVE

We compared pharmacokinetic and pharmacodynamic characteristics of generic and reference listed or original preparations of ropivacaine.

DESIGN

The current healthy volunteer study used a randomised, triple-blinded, cross-over equivalence design.

SETTING

Tertiary university hospital, Medical University of Vienna.

SUBJECTS: Healthy male volunteers (N=18) aged 18 to 60 years.

INTERVENTIONS: A series of three ultrasound-guided ulnar nerve blocks separated by at least 6 days were carried out on each volunteer. Reference listed ropivacaine (NaropinTM) was used for two blocks and a generic preparation of ropivacaine was used for the other block. Sensory block onset and duration were evaluated using loss of pinprick sensation.

MAIN OUTCOME MEASURES: Duration of sensory block was the primary outcome. Secondary outcomes included time-to-onset of sensory block, ropivacaine pharmacokinetics from venous blood samples and pH of the preparations. Equivalence was evaluated using the ratios of means and 90% confidence intervals (CIs) of log transformed data.

RESULTS

Equivalence was demonstrated for the primary outcome measure, the duration of sensory block [original : generic ratio 1.01 (90% CI 0.87 to 1.16); P < 0.007] and all pharmacokinetic variables. Equivalence could not be concluded for time-to-onset of sensory block [reference : generic ratio 0.80 (90% CI 0.63 to 1.03); P = 0.27], although reproducibility of this variable using our experimental model was lower than for other variables. The generic preparation was significantly more alkaline [difference 0.06 pH units (95% CI 0.04 to 0.07); P < 0.0001].

CONCLUSION

Our finding of equivalence for sensory block duration and key pharmacokinetic variables between a generic and original preparation of ropivacaine is reassuring. The significant, but small, difference in pH is not clinically important.

TRIAL REGISTRATION: EudraCT 2019-003148-61, German Clinical Trials Register (DRKS 00017750).

Для цитирования: Opfermann Philipp, Marhofer Peter, Hopkins Philip M, Columb Malachy O, Zadrazil Markus, Stimpfl Thomas, Marhofer Melanie, Zeitlinger Markus. Generic versus reference listed ropivacaine for peripheral nerve blockade: A randomised, triple-blinded, crossover, equivalence study in volunteers.. European journal of anaesthesiology. 2021. DOI: 10.1097/eja.0000000000001424.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.