MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s003300000578

Медицинская библиотека · European radiology · 2001

Malposition of catheters during voiding cystourethrography.

Rathaus V, Konen O, Shapiro M, Grunebaum M

Клинический случайСтатьяПеревод в очереди

Аннотация

The aim of this study was to report catheter malposition during voiding cystourethrography. Eight hundred forty-three voiding cystourethrography (265 males and 578 females, aged 1 week to 12 years, mean age 2 years) were performed during a period of 4 years. The conventional standard procedure was applied. In 3 cases with passed history of urinary tract infection the catheter entered directly into the ureter. In all these cases the uretero-vesical reflux was present on the same side where the catheter entered. It appears that insertion of a catheter into the ureter is possible only in the presence of an anomaly or pathology at the vesicoureteric junction.