MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12957-023-03191-7

Медицинская библиотека · World journal of surgical oncology · 2023

Single-port three-dimensional (3D) endoscopic-assisted breast surgery-preliminary results and patient-reported satisfaction in 145 breast cancer and gynecomastia cases.

Chia Clement Luck Khng, Sae-Lim Chayanee, Lai Hung-Wen, Chandrachamnong Korawan, Huang Hsin-I, Chen Dar-Ren, Chen Shou-Tung

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Minimal-accessed (robotic and endoscopic) breast cancer surgery is increasingly performed due to better cosmetic results and acceptable oncological outcomes. This study aims to demonstrate the clinical safety and patient-reported cosmetic satisfaction of single-port three-dimensional endoscopic-assisted breast surgery (S-P 3D EABS), which is our new endoscopic surgical innovation, in both malignant and benign breast conditions.

METHODS

Patients who underwent S-P 3D EABS from 1 August 2018 to 31 July 2022 in a single institution were enrolled. Clinical outcomes of this procedure were retrospectively reviewed, and the patient-reported cosmetic satisfaction was evaluated by a questionnaire and reported herein.

RESULTS

During the study period, 145 patients underwent 164 procedures of S-P 3D EABS. One hundred fifty (91.5%) procedures were endoscopic-assisted nipple-sparing mastectomy (S-P 3D E-NSM; 117 therapeutic procedures for breast cancer, 13 prophylactic mastectomies, 20 procedures for gynecomastia). Fourteen (8.5%) procedures of endoscopic-assisted breast-conserving surgery (S-P 3D E-BCS) were performed (12 S-P 3D E-BCS, 2 S-P 3D E-BCS with 3D videoscope-assisted partial breast reconstruction, which was 1 case of latissimus dorsi flap and 1 case of omental flap). The mean operative time was 245 ± 110 min in S-P 3D E-NSM and 260 ± 142 min in S-P 3D E-BCS. The mean intraoperative blood loss was 49.7 ± 46.9 ml in S-P 3D E-NSM and 32.8 ± 17.5 ml in S-P 3D E-BCS. Subnipple biopsy showed positive malignancy in 3 (2.6%) S-P 3D E-NSM patients. None of the S-P 3D E-BCS patients found margin involvement; however, 3 (2.6%) reported margin involvement in S-P 3D E-NSM patients. Thirty-two complications were found (24.6%): 7 (5.3%) transient nipple-areolar complex (NAC) ischemia, 7 (5.3%) partial NAC necrosis, 1 (0.7%) total NAC necrosis, and 1 (0.7%) implant loss. During the mean follow-up time of 34 months, there were 2 (1.5%) patients with locoregional recurrence, 9 (6.9%) distant metastasis, and 2 (1.5%) mortality. 78.6% (77/98) of patients answering the cosmetic-evaluated questionnaire reported good and excellent overall satisfaction.

CONCLUSIONS

S-P 3D EABS is a novel surgical innovation, which is able to perform safely in either malignant or benign breast conditions and offer promising cosmetic results.

Для цитирования: Chia Clement Luck Khng, Sae-Lim Chayanee, Lai Hung-Wen, Chandrachamnong Korawan, Huang Hsin-I, Chen Dar-Ren, Chen Shou-Tung. Single-port three-dimensional (3D) endoscopic-assisted breast surgery-preliminary results and patient-reported satisfaction in 145 breast cancer and gynecomastia cases.. World journal of surgical oncology. 2023. DOI: 10.1186/s12957-023-03191-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.