Masking in Active Comparator Designs in Pharmacovigilance: A Retrospective Bias Analysis on the Spontaneous Reporting of Thiazolidinediones and Cardiovascular Events.
Аннотация
INTRODUCTION
Masking is a reporting bias where drug safety signals are muffled by elevated reporting of other medications in spontaneous reporting databases. While the impact of masking is often limited, its effect when using restricted designs, such as active comparators, can be consequential.
METHODS
We used data from the US Food and Drugs Administration Adverse Event Reporting System (1999Q3-2013Q3) to study masking in a real-world example. Rosiglitazone, a thiazolidinedione with elevated reporting after safety concerns over cardiovascular risks, was the masking candidate. We hypothesized that stimulated reporting masked signals for another thiazolidinedione, pioglitazone. We computed estimates of proportional reporting ratios and information components, using the Bayesian confidence propagation neural network, for pioglitazone-myocardial infarction and pioglitazone-cardiac failure under unrestricted and active comparator designs, with and without the mask, before (1999Q3-2007Q1) and after (2007Q2-2013Q3) safety concerns. Relative change-in-estimates were computed to compare results with and without rosiglitazone.
RESULTS
From 1999Q3-2007Q1, relative change-in-estimates of proportional reporting ratio for pioglitazone-myocardial infarction was 0.00 in unrestricted design and 0.10 in active comparator, and for pioglitazone-cardiac failure, the change was 0.01 and 0.62, respectively. From 2007Q2-2013Q3, relative change-in-estimates for pioglitazone-myocardial infarction was 0.41 in unrestricted design and 18.00 in active comparator; the change for pioglitazone-cardiac failure was 0.04 and 1.03, respectively. Relative changes in estimates of information component mirrored these trends.
CONCLUSIONS
Masking can influence signal detection in active comparator designs where external events impact reporting rates in reference sets. Evaluating masking in related contexts is essential for drug safety monitoring and resource allocation for follow-up studies.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.