MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jhsa.2014.01.018

Медицинская библиотека · The Journal of hand surgery · 2014

Volar percutaneous screw fixation of the scaphoid: a cadaveric study.

Vaynrub Max, Carey Joseph N, Stevanovic Milan V, Ghiassi Alidad

СтатьяПеревод в очереди

Аннотация

PURPOSE: To test the efficacy of a previously described technique of angiocatheter-assisted instrument positioning in achieving a central screw position in a cadaveric model for volar percutaneous screw fixation (PSF) of the scaphoid and to quantify the damage to surrounding soft tissue and articular cartilage associated with the procedure.

METHODS

We performed fluoroscopically guided volar PSF of the scaphoid on 10 fresh cadaveric wrists. We then dissected the specimens, analyzed screw position in cross sections of the scaphoid, and described injury to nearby soft tissue structures as well as articular cartilage of the scaphotrapezial joint.

RESULTS

All 10 screws were positioned within the central third of the scaphoid on at least 2 of 3 cross sections, and 8 of 10 screws were positioned within the central third of the proximal pole. Two wrists required a transtrapezial trajectory for satisfactory screw positioning. None of the specimens sustained visible neurovascular damage, and 2 wrists revealed minor tendon damage. Trajectories involving the scaphotrapezial joint violated, on average, 7% of the scaphoid articular cartilage. With a transtrapezial trajectory, 11% of the trapezial cartilage was violated

CONCLUSIONS

Central positioning of the screw is biomechanically superior, and screw position within the central one third of the proximal pole has been associated with faster time to union. Volar PSF achieved satisfactory screw position in the scaphoid. The majority of wrists were amenable to PSF via the scaphotrapezial joint, though a transtrapezial approach was a viable alternative for wrists with restrictive anatomy. Both approaches minimally disrupted the scaphotrapezial joint and surrounding soft tissues.

TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic IV.

Для цитирования: Vaynrub Max, Carey Joseph N, Stevanovic Milan V, Ghiassi Alidad. Volar percutaneous screw fixation of the scaphoid: a cadaveric study.. The Journal of hand surgery. 2014. DOI: 10.1016/j.jhsa.2014.01.018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.