MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Archivos espanoles de urologia · 2014

Results of the treatment of anterior pelvic organ prolapse using the Perigee® system.

Elizalde Benito Francisco Xavier, Elizalde Benito Angel Gabriel, Urra Palos María, Quintana Martínez Ignacio, Elizalde Amatria Angel Gabriel

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To study the efficacy and safety of the Perigee® System for the treatment of anterior vaginal prolapse in our experience with a medium term follow-up.

METHODS

Prospective analysis on 48 consecutive patients with stage II-IV cystocele diagnosed from June 2006 until June 2009 using the Pelvic Organ Prolapse Quantitation classification without other associated prolapses. All diagnoses were done by a single urological specialist and follow-up is between 3 to 6 years. The questionnaire Patient Global Impression of Improvement was carried out before surgery, at the first follow up checking at one month, and at 6 and 12 months. The variables evaluated were age, presence of obesity, parity, prior hysterectomy, ASA class and stage of prolapse.

RESULTS

The result, evaluating the questionnaire Patient Global Impression of Improvement, was cured or improved in 40 (83.3%) patients and 87.5% according to the Pelvic Organ Prolapse Quantitation, with a recurrence rate of 6.25%. Intraoperative complications were observed in 12.5% of the patients, postoperative in 4.2% and 41.5% after hospital discharge, pain being the most common complication (16.6%). The key variables for procedural failure were age 65 years >, obesity, parity ≥ 2, prolapse stage ≥ III and prior hysterectomy (p <0.05).

CONCLUSIONS

In our series the Perigee® System allows anatomic repair with less morbidity, hospital stay and recovery time.

Для цитирования: Elizalde Benito Francisco Xavier, Elizalde Benito Angel Gabriel, Urra Palos María, Quintana Martínez Ignacio, Elizalde Amatria Angel Gabriel. Results of the treatment of anterior pelvic organ prolapse using the Perigee® system.. Archivos espanoles de urologia. 2014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.