DOI 10.1093/ejcts/ezag013

Медицинская библиотека · European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery · 2026

Automated Suture Securing Technology in Mitral Valve Surgery: A Strategy to Reduce Prosthetic Dehiscence?

Kahrovic Amila, Herkner Harald, Werner Paul, Angleitner Philipp, Coti Iuliana, Osipenko Kira, Lagler Heimo, Kocher Alfred, Ehrlich Marek, Zimpfer Daniel, Andreas Martin

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

This study aimed to assess long-term outcomes of automated titanium fasteners versus hand-tied knots in mitral valve surgery.

METHODS

In this retrospective, single-centre analysis, 2678 adult patients who underwent mitral valve repair or replacement between November 2008 and November 2024 at the Medical University of Vienna were included. Patients were grouped according to the suture-securing technique used: automated titanium fasteners versus hand-tied knots. The primary endpoint was prosthetic dehiscence (either mitral annuloplasty ring or valve replacement prosthesis) requiring reintervention. Secondary endpoints comprised ischaemic stroke, intracranial bleeding, and all-cause mortality during the follow-up period.

RESULTS

Among the study population, 1072 (40%) underwent mitral valve surgery using an automated titanium fastener device, and 1606 (60%) with conventional hand-tied sutures. A total of 31 patients (1.2%) had prosthetic dehiscence during the follow-up period. The risk of prosthetic dehiscence was significantly lower in the automated titanium fastener group in both univariable (crude sub-hazard ratio [sHR] 0.32; 95% confidence interval [CI], 0.12-0.86, P = .023) and multivariable competing risk regression analysis (adjusted sHR 0.34; 95% CI, 0.12-0.91, P = .033). Automated titanium fastener group was not associated with an increased risk of ischaemic stroke (adjusted sHR 0.92; 95% CI, 0.67-1.27, P = .600), intracranial bleeding (adjusted sHR 0.89; 95% CI, 0.52-1.52, P = .675), or all-cause mortality (adjusted hazard ratio 0.93; 95% CI, 0.74-1.18, P = .559).

CONCLUSIONS

The use of an automated titanium fastener device seems to be associated with a lower risk of prosthetic dehiscence in mitral valve surgery. Due to the limited number of prosthetic dehiscence events and the potential for residual confounding, the results should be interpreted with caution.

Для цитирования: Kahrovic Amila, Herkner Harald, Werner Paul, Angleitner Philipp, Coti Iuliana, Osipenko Kira, Lagler Heimo, Kocher Alfred, Ehrlich Marek, Zimpfer Daniel, Andreas Martin. Automated Suture Securing Technology in Mitral Valve Surgery: A Strategy to Reduce Prosthetic Dehiscence?. European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery. 2026. DOI: 10.1093/ejcts/ezag013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.