Morphological features in eyes with endophthalmitis after cataract surgery - histopathology and optical coherence tomography assessment.

Solborg Bjerrum Søren, Prause Jan Ulrik, Fuchs Josefine, la Cour Morten, Kiilgaard Jens F

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To assess the ocular damage that occurs in eyes with postoperative endophthalmitis after cataract surgery (PE) based on optical coherence tomography (OCT) retinal scans of PE eyes and histological specimens of eyes removed due to PE.

METHODS

Case-control study and case series. Fifty-one patients who had previously developed PE were clinically examined with OCT scans of the retina of both eyes. Histological specimens of 10 removed PE eyes were studied.

RESULTS

The OCT scans showed that PE eyes had a statistically significantly higher frequency of hyperdense elements on the internal limiting membrane (ILM) of the retina (14 eyes versus 3 eyes, p = 0.015) and a higher degree of retinal atrophy temporal to the fovea (13 eyes versus 1 eye, p = 0.013) compared to fellow eyes. The histopathological analyses showed the formation of epiretinal membranes, derangement of all retinal layers with a reduced number of nuclei in the nuclear layers, loss of photoreceptor outer segments and massive retinal gliosis.

CONCLUSIONS

Optical coherence tomography scans of the retina and histopathology analyses provide insights in the pathological process occurring in PE.

Для цитирования: Solborg Bjerrum Søren, Prause Jan Ulrik, Fuchs Josefine, la Cour Morten, Kiilgaard Jens F. Morphological features in eyes with endophthalmitis after cataract surgery - histopathology and optical coherence tomography assessment.. Acta ophthalmologica. 2015. DOI: 10.1111/aos.12858.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.