THE LABORATORY ASPECTS OF PROTEINURIA.
Аннотация
INTRODUCTION
The existence of proteinuria may be overlooked by applying the test strips. The aim of this study has been to determine the discrepancy between the findings ofproteinuria detected by test strips when compared to the results of its testing with the sulfosali- cylic acid.
MATERIAL AND
METHODS
The study sample consisted of 1106 subjects, who were divided into the proteinuria positive (test strips showed the presence of isolated proteinuria), and proteinuria negative group (microscopic examination revealed the presence of ≥10 fresh red blood cells4sL, and/or ≥1 dysmorphic erythrocyte/μL, and/or 10≥ leukocytes4uL, and or ≥1 cylinder, and/or ≥ 1 nonsquamous epithelial cells4μL, and/or ≥100 bacteria/μL). Both groups had the urine tested with sulfosalicylic acid. The chemical and microscopic examination of the urine was done by the analyzer LabUMat-UriSed.
RESULTS
Proteinuria was confirmed with the sulfosalicylic acid test in 96.5% ofsublects from group I and in 85.3% ofsubiects from group 2. Among the patients with the negative finding of proteinuria on the test strip and with the positive sulfosalicylic acid test there was a significantly higher number of those with pathological findings of erythrocytes, leukocytes, bacteria and cylinders in the urine when compared to those of the same group with negative sulfosalicylic acid test.
CONCLUSION
Sulfosalicylic acid test should be performed in cases of pathological microscopic findings in the urine in case of the presence of ≥10 fresh erythrocytes4iL and/or ≥ 1 dysmorphic eryth- rocyte/pL and/or 10≥ leukocytes/μL and/or 1≥ cylinder (except hyaline) and/or ≥1 nonsquamous epithelial cells/pL and/or≥ 100 bacterial pL even if the test strip examination is negative for proteinuria.
Другие публикации по теме
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.