Successful Right Sided Subcutaneous Implantable Cardioverter-Defibrillator Implantation in Situs Inversus Dextrocardia: A Case Report and Literature Review.

Karimian Bahareh, Haghjoo Majid, Ramezani Akam, Khajehei Mehrdad

СтатьяПеревод в очереди

Аннотация

This case report details the successful implantation of a subcutaneous implantable cardioverter-defibrillator (S-ICD) in a 70-year-old male with situs inversus dextrocardia, a rare congenital condition where the heart and visceral organs are reversed. The patient, with a history of ischemic heart disease and severe left ventricular dysfunction (ejection fraction 25%), required primary prevention of sudden cardiac death. Due to anatomical challenges with transvenous ICD placement and no need for pacing or resynchronization, an S-ICD was selected. Pre-procedural screening was modified by reversing electrode positions to accommodate the right-sided heart, ensuring eligibility across all sensing vectors. The S-ICD was implanted using a two-incision technique, positioning the generator in the right midaxillary line and the electrode along the left parasternal area. Defibrillation threshold testing confirmed effective termination of induced ventricular fibrillation with a 60 J shock. No complications occurred, and 1-month follow-up verified normal device function. This case demonstrates the adaptability and safety of S-ICD implantation in dextrocardia, emphasizing tailored screening and procedural adjustments. A review of existing literature shows consistent success with S-ICDs in similar patients, though device placement varies. This report adds to the evidence supporting S-ICD use in complex congenital anatomies, providing valuable guidance for clinicians.

Для цитирования: Karimian Bahareh, Haghjoo Majid, Ramezani Akam, Khajehei Mehrdad. Successful Right Sided Subcutaneous Implantable Cardioverter-Defibrillator Implantation in Situs Inversus Dextrocardia: A Case Report and Literature Review.. Clinical case reports. 2025. DOI: 10.1002/ccr3.71509.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.