In-depth analysis of T2Bacteria positive results in patients with concurrent negative blood culture: a case series.

Kalligeros Markos, Zacharioudakis Ioannis M, Tansarli Giannoula S, Tori Katerina, Shehadeh Fadi, Mylonakis Eleftherios

Клиническое исследованиеСтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

BACKGROUND

T2Bacteria assay uses T2 magnetic resonance (T2MR) technology for the rapid diagnosis of bacterial bloodstream infections (BSIs). This FDA cleared technology can detect 5 of the most prevalent pathogens causing bacteremia (Escherichia coli, Staphylococcus aureus, Klebsiella pneumoniae, Pseudomonas aeruginosa, and Enterococcus faecium). Because the significance of discordant results between the T2Bacteria assay and blood culture (BC) remains a challenge, in this case series we reviewed the medical records of patients who had a positive T2Bacteria test and a concurrent negative BC.

METHODS

Among 233 participants, we identified 20 patients with 21 (9%) discordant T2Bacteria-positive/BC-negative (T2+/BC-) results. We classified these results based on clinical cultures and clinical evidence.

RESULTS

When we analyzed these 21 discordant results in-depth, 11 (52.5%) fulfilled criteria for probable BSI, 4 (19%) for possible BSI, and 6 (28.5%) were presumptive false positives. Among the probable/possible BSIs, discordant results were often associated with patients diagnosed with closed space and localized infections [pyelonephritis (n = 7), abscess (n = 4), pneumonia (n = 1), infected hematoma (n = 1), and osteomyelitis (n = 1)]. Also, within the preceding 2 days of the T2+/BC- blood sample, 80% (16/20) of the patients had received at least one dose of an antimicrobial agent which was active against the T2Bacteria-detected pathogen.

CONCLUSIONS

In the majority of discrepant results, the T2Bacteria assay detected a plausible pathogen that was supported by clinical and/or microbiologic data. Discrepancies appear to be associated with closed space and localized infections and the recent use of effective antibacterial agents. The clinical significance and potential implications of such discordant results should be further investigated.

Для цитирования: Kalligeros Markos, Zacharioudakis Ioannis M, Tansarli Giannoula S, Tori Katerina, Shehadeh Fadi, Mylonakis Eleftherios. In-depth analysis of T2Bacteria positive results in patients with concurrent negative blood culture: a case series.. BMC infectious diseases. 2020. DOI: 10.1186/s12879-020-05049-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.