MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jmri.70368

Медицинская библиотека · Journal of magnetic resonance imaging : JMRI · 2026

Longitudinal 1H and 129Xe Lung MRI in Patients With Post-COVID Residual Lung Abnormalities.

Saunders Laura C, Collier Guilhem J, Smith Laurie J, Chan Ho-Fung, Hughes Paul J C, Strickland Scarlett, Gustafsson Lotta, Newman Thomas, Plowright Megan, Gabriel Zoë, Pearce Lily M, Grist James T, Ng Kher Lik, Harrison Arthur, Bolton Charlotte E, Bray Jody, Marshall Helen, Norquay Graham, Biancardi Alberto M, Ball Jimmy E, Stewart Neil J, Johnson Kevin M, Swift Andrew J, Rajaram Smitha, Blaikley John, Stanel Stefan, Collini Paul J, Mills Gary H, Lawson Rod, Brooke Jonathan, Goodwin Amanda T, Stewart Iain D, Ho Ling-Pei, Jacob Joseph, Meersmann Thomas, Pavlovskaya Galina E, Gleeson Fergus, Hall Ian P, Jenkins Gisli, Wild Jim M, Thompson A A Roger, UK‐ILD consortium

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

BACKGROUND

It is unclear how lung function may recover in patients with residual lung abnormalities (RLAs) following COVID-19 pneumonia.

PURPOSE: To evaluate lung function trends over time in patients with RLAs following hospitalization due to COVID-19.

STUDY TYPE: Prospective, multicenter longitudinal cohort study.

POPULATION: Twenty-four participants hospitalized due to COVID-19 with RLAs identified on CT ≥ 3 months postdischarge (median [IQR] age 69 (15) years; 3 female) underwent at least one MRI at 6 months (n = 16), 1 year (n = 19), or 2 years (n = 14).

FIELD STRENGTH/SEQUENCE: 1.5 T. Dynamic contrast enhanced (DCE) 3D spoiled gradient echo, 129Xe steady state free precession (ventilation), 129Xe 3D spoiled gradient echo multiple b-value (diffusion-weighted), 129Xe 4-echo flyback 3D radial (dissolved phase).

ASSESSMENT: Pulmonary blood flow, volume, and mean transit time (MTT) were calculated from DCE MRI. The fraction of 129Xe signal in the red blood cells to membrane (RBC:M) was calculated from the dissolved phase 129Xe acquisition. Ventilation defect percentage (VDP) was calculated from the 129Xe ventilation acquisition. Mean diffusive length scale (LmD) was calculated from the 129Xe diffusion-weighted acquisition.

STATISTICAL TESTS: Changes in metrics with time and associations between metrics were assessed using mixed-effect linear regression. Correlations were tested using Spearman's correlation coefficient. Regional differences were assessed using a Friedman's test with a Bonferroni adjustment. p < 0.05 was considered significant.

RESULTS

Pulmonary blood flow and MTT improved significantly over time (MTT: 6 months, 15.3 (IQR, 2.0); 1 year, 15.6 (1.4); 2 years, 15.0 (5.3); pulmonary blood flow: 6 months, 75.4 (IQR, 22.0); 1 year, 83.2 (47.4); 2 years, 107.3 (51.1)). RBC:M z-score was low at all three visits (6 months, -2.85 (0.98); 1 year, -2.44 (1.34); 2 years, -2.60 (1.39)), with no improvement with time (p = 0.993). VDP and LmD did not significantly change with time (VDP: p = 0.100; LmD: p = 0.166).

DATA

CONCLUSION

Improvements in lung perfusion were measured; however, there was no corresponding enhancement in RBC:M.

EVIDENCE LEVEL: Level 2.

TECHNICAL EFFICACY: Stage 3.

Для цитирования: Saunders Laura C, Collier Guilhem J, Smith Laurie J, Chan Ho-Fung, Hughes Paul J C, Strickland Scarlett, Gustafsson Lotta, Newman Thomas, Plowright Megan, Gabriel Zoë, Pearce Lily M, Grist James T, Ng Kher Lik, Harrison Arthur, Bolton Charlotte E, Bray Jody, Marshall Helen, Norquay Graham, Biancardi Alberto M, Ball Jimmy E, Stewart Neil J, Johnson Kevin M, Swift Andrew J, Rajaram Smitha, Blaikley John, Stanel Stefan, Collini Paul J, Mills Gary H, Lawson Rod, Brooke Jonathan, Goodwin Amanda T, Stewart Iain D, Ho Ling-Pei, Jacob Joseph, Meersmann Thomas, Pavlovskaya Galina E, Gleeson Fergus, Hall Ian P, Jenkins Gisli, Wild Jim M, Thompson A A Roger, UK‐ILD consortium. Longitudinal 1H and 129Xe Lung MRI in Patients With Post-COVID Residual Lung Abnormalities.. Journal of magnetic resonance imaging : JMRI. 2026. DOI: 10.1002/jmri.70368.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.