Training model for the fetal myelomeningocele correction with multiportal endoscopic technique.

da Costa Marcos Devanir Silva, Nicacio Jardel Mendonça, Dastoli Patricia Alessandra, Suriano Italo Capraro, Sarmento Stéphanno Gomes Pereira, Barbosa Mauricio Mendes, Moron Antonio Fernandes, Cavalheiro Sergio

СтатьяПеревод в очереди

Аннотация

PURPOSE: The recent history of myelomeningocele has shown that treatment during the fetal life may reduce the risk of developing hydrocephalus in individuals by approximately 50%. Thus, a significant advancement involves fetal surgery performed through an endoscopic technique in which portals are placed to introduce the forceps and laparoscopic instruments. However, the development of this technique requires training; therefore, this study aimed to develop a training model for fetal myelomeningocele repair technique with multi-portal endoscopy.

METHODS

Two stages of endoscopic technique development were performed. The first stage consisted of exercises in order to familiarize the surgeon with 2D-vision endoscopic surgery, associated with the application of exercises focused on surgical skills, such as the development of laparoscopic knots in a synthetic model. The second stage involved the creation and application of the stages of myelomeningocele closure with a non-living animal model consisting of a chicken breast to simulate the myelomeningocele and a basketball to simulate the gravid uterus, in which perforations were made to introduce vascular introducers (portals) that, as in vivo, are used as portals (trocars) for the introduction of laparoscopic instruments. Overall, two different scenarios with three portals and two portals were tested.

RESULTS

In three-portal simulator, the triangular apex trocar was used for the introduction of 4-mm 0° or 30° optics or even Minop type neurodoscope (Aesculap®, Germany) that was operated by the assistant surgeon; the other two portals are used for the introduction of laparoscopic instruments. Thus, the surgeon is able to perform maneuvers bimanually since dissection to laparoscopic sutures. In two-portal simulator, the surgeon and assistant stay side by side and one of the portals is used for the optic and the other for the laparoscopic instruments. There is no possibility of bimanual dissection in this method.

CONCLUSION

Realistic simulation models for endoscopic fetal surgery for myelomeningocele correction are easily performed and help develop the necessary skills for fetal surgery teams.

Для цитирования: da Costa Marcos Devanir Silva, Nicacio Jardel Mendonça, Dastoli Patricia Alessandra, Suriano Italo Capraro, Sarmento Stéphanno Gomes Pereira, Barbosa Mauricio Mendes, Moron Antonio Fernandes, Cavalheiro Sergio. Training model for the fetal myelomeningocele correction with multiportal endoscopic technique.. Child's nervous system : ChNS : official journal of the International Society for Pediatric Neurosurgery. 2023. DOI: 10.1007/s00381-023-05893-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.