MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/scs.0000000000012368

Медицинская библиотека · The Journal of craniofacial surgery · 2026

Correction of Mandibular Asymmetry With Bilateral Asymmetric Custom-Made 3D Implant.

Bayram Yalcin, Zor Fatih, Kilic Sedat, Acikel Cengiz Han, Kulahci Yalcin, Cordes Emma

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Unilateral mandibular hypoplasia affects not only the involved side but also the contralateral hemimandible. Thus, treatment must address bilateral deformities. The authors present a novel bilateral CAD/CAM titanium onlay implant design for unilateral mandibular hypoplasia and evaluate outcomes using objective and patient-reported measures.

PATIENTS AND

METHODS

Thin-slice CT scans were processed with Mimics® software. The unaffected hemimandible was repositioned to the midline using the TMJ as a pivot, and its mirror image was used to create the contralateral side. Bilateral custom implants were generated through the subtraction of corrected from native images and 3D printed. Eight male patients underwent correction via extraoral incision, with fat grafting for contour refinement. Follow-up was at least 12 months. PROMs included the Appearance Evaluation Subscale (AES) of the Multidimensional Body Self-Relations Questionnaire and the Rosenberg Self-Esteem Scale (RSE). Objective outcomes were assessed with the Facial Asymmetry Index (FAI).

RESULTS

Five patients had congenital asymmetry, and three had post-traumatic deformities. All tolerated surgery without early complications. Fat grafting was used in five cases, four of which involved hemifacial microsomia. AES and RSE scores significantly improved at 12 months compared with preoperative values. FAI also demonstrated a significant reduction in facial asymmetry.

CONCLUSION

Correction of unilateral mandibular hypoplasia creates bilateral deformities. Our bilateral CAD/CAM titanium implant approach provides a novel solution, though most patients also require soft tissue adjustment. Despite being time-consuming and costly, future technological advances are expected to increase efficiency and reduce expense.

Для цитирования: Bayram Yalcin, Zor Fatih, Kilic Sedat, Acikel Cengiz Han, Kulahci Yalcin, Cordes Emma. Correction of Mandibular Asymmetry With Bilateral Asymmetric Custom-Made 3D Implant.. The Journal of craniofacial surgery. 2026. DOI: 10.1097/scs.0000000000012368.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.