Are Viscoelastometric Assays of Old Generation Ready for Disposal? Comment on Volod et al. Viscoelastic Hemostatic Assays: A Primer on Legacy and New Generation Devices. J. Clin. Med. 2022, 11, 860.

Bareille Marion, Lecompte Thomas, Mullier François, Roullet Stéphanie

СтатьяПеревод в очереди

Аннотация

With the advent of new viscoelastometric hemostatic assay (VHA) devices, with ready-to-use cartridge reagents allowing for their use by people without special laboratory skills, the appreciation of the actual clinical value of VHAs in settings such as severe trauma, post-partum hemorrhage, cardiac surgery and liver transplantation still needs to be fully validated. While two of the newest versions remain based on a 'cup and pin' system (ROTEM® sigma, ClotPro®), two other new devices (TEG® 6s, Quantra®) rely on very different technologies: clotting blood is no longer in contact with the probe and challenged by oscillation of one of the components but explored with ultrasound exposure. A systematic literature search (including Sonoclot®) retrieved 20 observational studies (19 prospective). Most studies pointed to imperfect agreements, highlighting the non-interchangeability of devices. Only a few studies, often with a limited number of patients enrolled, used a clinical outcome. No study compared VHA results with conventional laboratory assays obtained through a rapid tests panel. Clinical evidence of the utility of the new VHAs largely remains to be proven through randomized clinical trials, with clinically relevant outcomes, and compared to rapid panel hemostasis testing. The availability of new, improved VHA devices provides an impetus and an opportunity to do so.

Для цитирования: Bareille Marion, Lecompte Thomas, Mullier François, Roullet Stéphanie. Are Viscoelastometric Assays of Old Generation Ready for Disposal? Comment on Volod et al. Viscoelastic Hemostatic Assays: A Primer on Legacy and New Generation Devices. J. Clin. Med. 2022, 11, 860.. Journal of clinical medicine. 2023. DOI: 10.3390/jcm12020477.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.