MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.talanta.2025.128799

Медицинская библиотека · Talanta · 2025

Portable detection system for identifying unknown liquid drugs.

Jeon Minji, Kwak Yeon Hwa, Kim Junsub, Yu Woo Jong, Kim Yong Ho, Ju Byeong-Kwon, Kim Kunnyun

СтатьяПеревод в очереди

Аннотация

Detecting and identifying drugs at an incident scene is crucial for swift and accurate investigations. Existing drug detectors primarily analyze purified drugs by capturing particle or vapor samples, and these devices are often bulky, expensive, and inconvenient for field use. In this study, we present a portable detection system using a multichannel surface acoustic wave (SAW) sensor for identifying unknown liquid drugs. This sensor, based on Love-wave technology operating at 318 MHz, enhances sensitivity and enables detection through an immunoassay method. Each sensor channel was functionalized with a drug conjugated to bovine serum albumin (BSA). To detect and identify an unknown drug, the unknown sample was mixed with a multi-antibody (multi-Ab) solution and injected into the sensor. Unbound antibodies adhered to the corresponding drug-BSA complex, resulting in a frequency shift due to the mass loading effect. This rapid binding process produced results within 1 min. The portable system integrates a custom-made frequency analyzer and detection module, forming a handheld device weighing less than 250g, suitable for real-time field analysis. The portable system successfully detected nine drug types, including methamphetamine (MA), morphine, cocaine, ketamine, methylenedioxy pyrovalerone (MDPV), fentanyl, heroin, zolpidem, and methcathinone. This innovative technology offers a cost-effective, portable solution for on-site drug identification, significantly improving detection speed, selectivity, and sensitivity to enhance investigative efficiency.

Для цитирования: Jeon Minji, Kwak Yeon Hwa, Kim Junsub, Yu Woo Jong, Kim Yong Ho, Ju Byeong-Kwon, Kim Kunnyun. Portable detection system for identifying unknown liquid drugs.. Talanta. 2025. DOI: 10.1016/j.talanta.2025.128799.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.