Clinical microbiology and infection : the official publication of the European Society of Clinical Microbiology and Infectious Diseases · 2019

Performance of differential time to positivity as a routine diagnostic test for catheter-related bloodstream infections: a single-centre experience.

Историческая статьяСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Orihuela-Martín J, Rodríguez-Núñez O, Morata L, Cardozo C, Puerta-Alcalde P, Hernández-Meneses M, Ambrosioni J, Linares L, Bodro M, de Los Angeles Guerrero-León M, Del Río A, Garcia-Vidal C, Almela M, Pitart C, Marco F, Soriano A, Martínez J A

Аннотация

OBJECTIVE: To assess the performance of differential time to positivity (DTP) for the diagnosis of catheter-related bloodstream infections (CRBSI).

METHODS: From all episodes of bloodstream infections (BSI) diagnosed during a 15-year period (2003-17) those in which a paired set of blood cultures drawn from a catheter and a peripheral vein were positive for the same microorganism and had a clinically and/or microbiologically defined source were selected. To assess diagnostic discrimination ability and accuracy of DTP for CRBSI, area under the receiver operating characteristic curves (AUC) and performance characteristics of a DTP ≥2 h were computed.

RESULTS: A total of 512 BSI were included, of which 302 (59%) were CRBSI. Discrimination ability of DTP was low for Staphylococcus aureus (AUC 0.656 ± 0.06), coagulase-negative staphylococci (AUC 0.618 ± 0.081), enterococci (AUC 0.554 ± 0.117) and non-AmpC-producing Enterobacteriaceae (AUC 0.653 ± 0.053); moderate for Pseudomonas aeruginosa (AUC 0.841 ± 0.073), and high for AmpC-producing Enterobacteriaceae (AUC 0.944 ± 0.039). For the entire sample, DTP had a low-to-moderate discrimination ability (AUC 0.698 ± 0.024). A DTP ≥2 h has a low sensitivity for coagulase-negative staphylococci (60%) and very low for S. aureus (34%), enterococci (40%) and non-AmpC-producing Enterobacteriaceae (42%). A DTP cut-off of 1 h improved sensitivity (90%) for AmpC-producing Enterobacteriaceae.

CONCLUSIONS: Differential time to positivity performs well for diagnosing CRBSI only when AmpC-producing Enterobacteriaceae and P. aeruginosa are involved. Performance is low for common Gram-positive organisms and non-AmpC-producing enteric bacilli; a negative test should not be used to rule out CRBSI due to these microorganisms. A DTP ≥1 h may improve accuracy for AmpC-producing Enterobacteriaceae, particularly Enterobacter spp.