MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00421-020-04478-3

Медицинская библиотека · European journal of applied physiology · 2020

Effects of a cooling vest with sham condition on walking capacity in heat-sensitive people with Multiple Sclerosis.

Buoite Stella Alex, Pasquin Fulvio, Morrison Shawnda A, Morelli Maria Elisa, Dinoto Alessandro, Bratina Alessio, Bosco Antonio, Sartori Arianna, Giudici Fabiola, Manganotti Paolo

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

PURPOSE: Heat sensitivity is a common contraindication in people with Multiple Sclerosis (pwMS), and physical fatigue is one of the most frequently reported symptoms that can affect quality of life. Increases in body temperature may exacerbate fatigue and heat-related symptoms. Decreasing body temperature via cooling devices may mitigate disease symptoms and improve physical abilities and quality of life. This study evaluates the effects of a cooling vest with sham condition on walking capacity using a commercially-available cooling vest specifically designed for pwMS.

METHODS

A counter-balanced, cross-over design was used to assess the effects of a cooling vest (CryoVest Comfort, CryoInnov, France) (COLD) from a menthol-induced sham condition (CON) on ground walking time to exhaustion (Tex, s) and distance at exhaustion (Dex, m) in ambulatory pwMS. Secondary outcomes were heart rate (HR, bpm), thermal sensation (Tsens), skin chest (Tchest) and back (Tback) temperature.

RESULTS

Ten females with Multiple Sclerosis (59 ± 9 years, EDSS 3.0-5.5) participated to the study. During COLD, pwMS walked significantly longer (1896 ± 602 vs. 1399 ± 404 s, p < 0.001) and farther (1879 ± 539 vs. 1302 ± 318 m, p < 0.001) than CON. Importantly, Tsens and HR at exhaustion were not significantly different between conditions, although Tchest (- 2.7 ± 1.8 °C, p < 0.01) and Tback (- 3.9 ± 1.8 °C, p < 0.001) were lower at volitional fatigue during COLD.

CONCLUSION

The lightweight cooling vest improved total walking time and distance in heat-sensitive pwMS. These physiological improvements were likely due to feeling perceptually cooler in the COLD trial, compared to the corresponding point of fatigue in the CON condition.

Для цитирования: Buoite Stella Alex, Pasquin Fulvio, Morrison Shawnda A, Morelli Maria Elisa, Dinoto Alessandro, Bratina Alessio, Bosco Antonio, Sartori Arianna, Giudici Fabiola, Manganotti Paolo. Effects of a cooling vest with sham condition on walking capacity in heat-sensitive people with Multiple Sclerosis.. European journal of applied physiology. 2020. DOI: 10.1007/s00421-020-04478-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.