Variability in Cystatin C- and Creatinine-estimated Glomerular Filtration Rate in Adults With Spina Bifida.

Kisty Stephen, Korth Sarah A, Abramovitz Blaise W, Adenaiye Oluwasanmi, Rusilko Paul, Dicianno Brad E

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To determine if serum cystatin C, which does not depend on muscle mass, is a potential alternative measure of kidney function in individuals with Spina Bifida and lower urinary tract dysfunction. Assessment using serum creatinine to estimate glomerular filtration rate is often compromised in this population because of decreased muscle mass from paralysis, which varies over spinal lesion levels and sub-phenotypes. We hypothesized creatinine-based formulas overestimate glomerular filtration rate at higher lesion levels relative to cystatin C-based formulas, and cystatin C-based equations provide stable estimates.

METHODS

We retrospectively analyzed data from 155 adults with Spina Bifida. Estimated glomerular filtration rates from 5 equations (Cr-eGFR-2009, Cr-eGFR-2021, CysC-eGFR-2012, Zappitelli-CysC-eGFR, and CrCysC-eGFR-2021) were compared across 5 lesion levels and 2 Spina Bifida sub-phenotypes (myelomeningocele vs non-myelomeningocele).

RESULTS

Creatinine-based estimated glomerular filtration rate increased with higher lesion levels (both P <.001), overestimating kidney function by a median of 12 mL/min/1.73 m² in thoracic-level myelomeningocele compared with cystatin C estimates. All 3 cystatin C-based formulas were stable across lesion levels (P >.39) and highly correlated (ρ = 0.84-0.94); P30 exceeded 90% for every pair. We identified biases up to ±7.8 mL/min/1.73 m² and limits of agreement wider than ±40 mL/min/1.73 m².

CONCLUSION

Significant discrepancies were observed among creatinine-based equations, which consistently estimated kidney function to be higher at higher lesion levels (relative to cystatin C) and in myelomeningocele. Cystatin C-based estimates were stable regardless of lesion level. However, clinicians should be cautious about the interchangeability of cystatin C-based estimates.

Для цитирования: Kisty Stephen, Korth Sarah A, Abramovitz Blaise W, Adenaiye Oluwasanmi, Rusilko Paul, Dicianno Brad E. Variability in Cystatin C- and Creatinine-estimated Glomerular Filtration Rate in Adults With Spina Bifida.. Urology. 2025. DOI: 10.1016/j.urology.2025.12.012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.