MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/medicina61091641

Медицинская библиотека · Medicina (Kaunas, Lithuania) · 2025

Hypothermic Machine Perfusion vs. Static Cold Storage in Kidney Transplantation: A Retrospective Paired-Kidney Study from Latvia.

Plūme Pāvils, Losevs Igors, Loseva Elizabete Anna, Maļcevs Aleksandrs, Suhorukovs Vadims, Jegorova Olga, Ševeļovs Viktors, Jušinskis Jānis

СтатьяПеревод в очереди

Аннотация

Background and

Objectives

Kidney transplantation remains the gold-standard treatment for end-stage renal disease (ESRD). For deceased donor transplantation, optimal allograft preservation represents a critical determinant of success. While static cold storage (SCS) has been the historical standard, hypothermic machine perfusion (HMP) has emerged in recent decades as a technologically advanced alternative. However, comparative data from smaller-volume centers utilizing exclusively donation after brain death (DBD) donors remain scarce. Materials and

Methods

This retrospective single-center study included 94 patients who received kidney transplants from deceased DBD donors between January 2018 and December 2024. We employed a paired kidney study design where one kidney from each donor was preserved using HMP (LifePort, set at 30/20 mm Hg pressure), while the contralateral kidney was stored in SCS. Parameters compared were creatinine concentration in recipient serum after transplantation, DGF, acute rejection and hospital stay.

Results

The HMP group had a significantly longer cold ischemia time (CIT) (18.09 ± 5.91 h, range: 6.5-34.0 h) compared to the SCS group (12.36 ± 5.18 h, range: 4.0-23.0 h; p < 0.005). The DGF rate was significantly lower in the HMP group (4.3%) than the SCS group (25.5%) (p = 0.004). HMP was also associated with a shorter mean hospitalization (11.81 vs. 15.66 days, p = 0.008) and superior early graft function, particularly in kidneys with CIT ≥ 18 h, which showed significantly lower serum creatinine at day 14 (124.48 vs. 164.89 µmol/L, p = 0.036).

Conclusions

HMP usage in kidney transplantation decreased the possibility for DGF in DBD donors and shortened the post-op hospitalization time. It is a feasible method for kidney storage before transplantation even in a case of prolonged CIT.

Для цитирования: Plūme Pāvils, Losevs Igors, Loseva Elizabete Anna, Maļcevs Aleksandrs, Suhorukovs Vadims, Jegorova Olga, Ševeļovs Viktors, Jušinskis Jānis. Hypothermic Machine Perfusion vs. Static Cold Storage in Kidney Transplantation: A Retrospective Paired-Kidney Study from Latvia.. Medicina (Kaunas, Lithuania). 2025. DOI: 10.3390/medicina61091641.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.