DOI 10.1016/j.jaccas.2026.108685
Transjugular Leadless Pacemaker in a Preschool Child With Nickel-Titanium Allergy.
Аннотация
BACKGROUND
Leadless pacemakers (L-PMs) have limited clinical application in low-weight young pediatric patients. Conventional transvenous pacemakers carry infection/allergy risks, with no established L-PM implantation protocols for metal-allergic pediatric populations.
CASE SUMMARY: A 4-year-old child with third-degree atrioventricular block had previously undergone 3 failed transvenous pacemaker implantations, each complicated by poor incisional healing and skin ulceration of the subcutaneous pockets. Patch testing confirmed metal allergy. A leadless single-chamber pacemaker (Micra VR, Medtronic) was successfully implanted via the right internal jugular vein.
DISCUSSION: Pediatric metal allergy to pacemaker casings is rare, and conventional pacing is unfeasible in such cases. Literature on transjugular L-PM implantation in low-weight children with nickel-titanium allergy is scarce, with no standardized venous access or procedural approaches reported.
TAKE-HOME MESSAGE: Transjugular L-PM implantation is a viable alternative for low-weight pediatric patients with pacemaker metal allergy and failed conventional pacing, providing a critical technical pathway for this high-risk population.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.