MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.transproceed.2018.03.008

Медицинская библиотека · Transplantation proceedings · 2018

Recurrent Bacteremia After Heart Transplantation Due to Abandoned Lead Fragment in an Anonymous Vein-A Case Report.

Burger H, Ziegelhoeffer T, Schoenburg M, Richter M

Клинический случайСтатьяПеревод в очереди

Аннотация

Heart transplantation (HTx) represents the "gold standard" in end-stage heart failure therapy. Due to their severe heart failure and for prevention of sudden cardiac death, the majority of patients presenting for HTx will have a history of an implanted cardioverter-defibrillator (ICD). Usually, within the scope of HTx, all cardiac-implanted electronic device components are removed. In rare cases these efforts fail and some material remains. The abandoned lead fragments can cause serious complications. The case presented herein involves a patient with recurrent bacteremia after successful HTx originating from an abandoned and infected lead fragment. In 2016, a 64-year-old man received a donor heart transplant due to end-stage heart failure. Unfortunately, during the procedure, not all components of an ICD implanted in 2007 could be removed. An initially event-free period was followed by recurrent fever attacks and staphylococcal bacteremia was diagnosed. After an extensive search, the source of the bacteremia was identified by positron emission tomography-computed tomography (PET-CT), and percutaneous extraction of the abandoned and infected ICD lead fragment was scheduled. The fragment was extracted using a minimally invasive approach via percutaneous femoral vein access. The patient was discharged 3 days later, with no further complications. This case highlights the need for conscientious and complete removal of foreign material in the HTx setting. Difficult-to-diagnose sources of infection could be reliably identified by PET-CT. When required, extraction of the foreign body should be done using a minimally invasive approach.

Для цитирования: Burger H, Ziegelhoeffer T, Schoenburg M, Richter M. Recurrent Bacteremia After Heart Transplantation Due to Abandoned Lead Fragment in an Anonymous Vein-A Case Report.. Transplantation proceedings. 2018. DOI: 10.1016/j.transproceed.2018.03.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.