DOI 10.1016/j.ejrad.2023.111262
Optimal CT windowing on low-monoenergetic images using a simplex algorithm-based approach for abdominal inflammatory processes.
Аннотация
BACKGROUND
OBJECTIVES
To determine optimal window settings for conspicuity of abdominal inflammatory processes on 50 keV low-monoenergetic images derived from dual-energy spectral CT (DECT).
METHODS
A retrospective study of 30 patients with clinically proven pancreatitis (15/30) or pyelonephritis (15/30) with inflammatory lesions visible on DECT scans were selected to serve as reference populations. 50 keV low-monoenergetic images in the portal venous phase were iteratively evaluated by 6 abdominal radiologists in twenty-one different windows (7-350HU center; 120-580HU width), selected using a simplex optimization algorithm. Each reader graded the conspicuity of the parenchymal hypodense lesions and image background quality. Three-dimensional contour maps expressing the relationship between overall reader grade and window center and width were constructed and used to find the ideal window for inflammatory pancreatic and renal processes and the image background quality. Finally, 15 appendicitis cases were reviewed on optimal pancreas and kidney windows and the manufacturer recommended conventional abdominal window settings for conventional imaging.
RESULTS
Convergence to optimal windowing was achieved based upon a total of 3,780 reads (21 window settings × 6 readers × 15 cases for pancreas and kidney). Highest conspicuity grade (>4.5 ± 0.0) for pancreas inflammatory lesions was seen at 116HU/430HU, whereas hypodense pyelonephritis had highest conspicuity at 290HU/570HU. This rendered an ideal "compromise" window (>4 ± 0.2) of 150HU/450HU which differed substantially from conventional manufacturer recommended settings of 50HU/380HU (2.1 ± 1.0, p = 0.00001). Appendix mucosal enhancement was best visualized at manufacturer settings.
CONCLUSIONS
Optimal visualization of inflammatory processes in abdominal organs on 50 keV low-monoenergetic images may require tailored refinement of window settings.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.