MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mat.0000000000002403

Медицинская библиотека · ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2025

Understanding Platelet Activation in the Aeson Bioprosthetic Total Artificial Heart: Insights From Aspirin Treatment and Outcomes.

Smadja David M, Roux de Bezieux Joseph, Peronino Christophe, Jilet Léa, Ivak Peter, Pya Yuri, Philippe Aurélien, Latremouille Christian, Gustafsson Finn, Ramjankhan Faiz Z, Roussel Jean Christian, Courbebaisse Marie, Parfait Béatrice, Lebeaux David, Friedlander Gérard, Vincentelli André, Flecher Erwan, Gaussem Pascale, Jansen Piet, Netuka Ivan

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

This study aimed to assess platelet activation following implantation of the Aeson bioprosthetic total artificial heart (A-TAH). We monitored plasma levels of platelet activation markers in patients receiving A-TAH support (n = 16) throughout the follow-up period. Before implantation, soluble CD40 ligand (sCD40L) levels averaged 3,909.06 pg/ml (standard deviation [SD] = 3,772.37), remaining stable postimplantation at 3,964.56 pg/ml (SD = 2,198.85) during months 1-3 and at 3,519.27 pg/ml (SD = 1,647.04) during months 3-6. Similarly, P-selectin (sP-sel) levels were 35,235.36 pg/ml (SD = 14,940.47) before implantation, stabilizing to 33,158.96 pg/ml (SD = 9,023.11) (1-3 months) and 31,022.58 pg/ml (SD = 9,249.95) (3-6 months). Preimplantation platelet factor 4 (PF4) measured 2,593.47 ng/ml (SD = 2,167.85), remaining consistent at 2,136.10 ng/ml (SD = 1,264.47) (1-3 months) and 1,991.26 ng/ml (SD = 1,234.16) (3-6 months). Levels of neutrophil-activating peptide 2 (NAP2) were also steady, measuring 785.63 ng/ml (SD = 605.26) preimplantation, 935.10 ng/ml (SD = 517.73) at 1-3 months, and 907.21 ng/ml (SD = 501.96) at 3-6 months postimplantation. Importantly, neither aspirin nor heparin treatment affected these platelet biomarker levels. No correlation was observed between platelet activation marker levels and clinical outcomes such as pericardial effusion, nor with the timing of aspirin initiation and drain removal. Our findings confirm that A-TAH does not trigger platelet activation. The lack of association between aspirin, platelet activation, and clinical outcomes suggests the possibility of discontinuing antiplatelet therapy following A-TAH implantation in the future.

Для цитирования: Smadja David M, Roux de Bezieux Joseph, Peronino Christophe, Jilet Léa, Ivak Peter, Pya Yuri, Philippe Aurélien, Latremouille Christian, Gustafsson Finn, Ramjankhan Faiz Z, Roussel Jean Christian, Courbebaisse Marie, Parfait Béatrice, Lebeaux David, Friedlander Gérard, Vincentelli André, Flecher Erwan, Gaussem Pascale, Jansen Piet, Netuka Ivan. Understanding Platelet Activation in the Aeson Bioprosthetic Total Artificial Heart: Insights From Aspirin Treatment and Outcomes.. ASAIO journal (American Society for Artificial Internal Organs : 1992). 2025. DOI: 10.1097/mat.0000000000002403.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.