MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/lungindia.lungindia_594_25

Медицинская библиотека · Lung India : official organ of Indian Chest Society · 2026

Concordance between different tools monitoring progression in interstitial lung diseases at 6 months-A prospective observational study.

Itishree Singh, Puneet Saxena, Abhishek Kumar, Sivasami Kartik, Virender Malik, Sankar J, Akhil K Ravi, Saurabh Tiwari, Prashant Kumar, Harsh Jain

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND AIMS: Interstitial lung disease (ILD) encompasses a wide variety of disorders with variable progression patterns. Monitoring typically involves assessing dyspnoea scores, spirometry parameters, 6-minute walk test (6MWT) parameters, and high-resolution CT (HRCT) scans. The agreement between the relative changes in these parameters over time is not known. To evaluate the concordance between changes in clinical, functional, physiological, and radiological parameters over 6 months in a diverse ILD cohort.

SETTINGS AND

DESIGN

Prospective observational study conducted from 01 July 2022 to 31 January 2024 at a tertiary care teaching hospital.

METHODS AND PATIENTS: Ninety-nine ILD patients underwent baseline and 6-month assessments of dyspnoea (mMRC), forced vital capacity (FVC), six-minute walk distance (6MWD), distance-saturation product (DSP), and HRCT. Patients were categorised as having lung-restricted or systemic disease-associated ILD. Changes were classified using established minimal clinically important differences. Concordance was analysed using weighted kappa; correlations were evaluated with Spearman's test.

RESULTS

Of 99 patients, 67.7% had ILD secondary to a systemic condition. Correlations between FVC, DSP, and 6MWD were moderate to strong both at baseline and at 6 months. Concordance among changes in clinical scores, FVC, 6MWD, and HRCT at the 6-month follow-up was low, with weighted-kappa values ranging from 0.023 to 0.158 for the overall study group. The strongest agreement was observed between clinical scores and FVC. The concordance was similarly poor in both subgroups.

CONCLUSIONS

Despite moderate baseline correlations, changes in different ILD monitoring parameters showed poor agreement, underscoring the multidimensional nature of disease progression. Comprehensive, multimodal follow-up remains essential, and multicentre validation is warranted.

Для цитирования: Itishree Singh, Puneet Saxena, Abhishek Kumar, Sivasami Kartik, Virender Malik, Sankar J, Akhil K Ravi, Saurabh Tiwari, Prashant Kumar, Harsh Jain. Concordance between different tools monitoring progression in interstitial lung diseases at 6 months-A prospective observational study.. Lung India : official organ of Indian Chest Society. 2026. DOI: 10.4103/lungindia.lungindia_594_25.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.