DOI 10.1128/jcm.01679-15

Медицинская библиотека · Journal of clinical microbiology · 2016

Evaluation of the FilmArray Blood Culture Identification Panel: Results of a Multicenter Controlled Trial.

Salimnia Hossein, Fairfax Marilynn R, Lephart Paul R, Schreckenberger Paul, DesJarlais Sharon M, Johnson J Kristie, Robinson Gwen, Carroll Karen C, Greer Amy, Morgan Margie, Chan Raymond, Loeffelholz Michael, Valencia-Shelton Frances, Jenkins Stephen, Schuetz Audrey N, Daly Judy A, Barney Trenda, Hemmert Andrew, Kanack Kristen J

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Sepsis is a major cause of morbidity, mortality, and increased medical expense. Rapid diagnosis improves outcomes and reduces costs. The FilmArray blood culture identification panel (BioFire Diagnostics LLC, Salt Lake City, UT), a highly multiplexed PCR assay, can identify 24 etiologic agents of sepsis (8 Gram-positive, 11 Gram-negative, and 5 yeast species) and three antimicrobial resistance genes (mecA, vanA/B, and blaKPC) from positive blood culture bottles. It provides results in about 1 h with 2 min for assay setup. We present the results of an eight-center trial comparing the sensitivity and specificity of the panel with those of the laboratories' standard phenotypic identification techniques, as well as with molecular methods used to distinguish Acinetobacter baumannii from other members of the A. calcoaceticus-A. baumannii complex and to detect antimicrobial resistance genes. Testing included 2,207 positive aerobic blood culture samples, 1,568 clinical and 639 seeded. Samples were tested fresh or were frozen for later testing within 8 h after the bottles were flagged as positive by an automated blood culture system. At least one organism was detected by the panel in 1,382 (88.1%) of the positive clinical specimens. The others contained primarily off-panel organisms. The panel reported multiple organisms in 81 (5.86%) positive clinical specimens. The unresolved blood culture identification sensitivity for all target detections exceeded 96%, except for Klebsiella oxytoca (92.2%), which achieved 98.3% sensitivity after resolution of an unavoidable phenotypic error. The sensitivity and specificity for vanA/B and blaKPC were 100%; those for mecA were 98.4 and 98.3%, respectively.

Для цитирования: Salimnia Hossein, Fairfax Marilynn R, Lephart Paul R, Schreckenberger Paul, DesJarlais Sharon M, Johnson J Kristie, Robinson Gwen, Carroll Karen C, Greer Amy, Morgan Margie, Chan Raymond, Loeffelholz Michael, Valencia-Shelton Frances, Jenkins Stephen, Schuetz Audrey N, Daly Judy A, Barney Trenda, Hemmert Andrew, Kanack Kristen J. Evaluation of the FilmArray Blood Culture Identification Panel: Results of a Multicenter Controlled Trial.. Journal of clinical microbiology. 2016. DOI: 10.1128/jcm.01679-15.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.