MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10278-025-01794-y

Медицинская библиотека · Journal of imaging informatics in medicine · 2025

Artificial Intelligence Detection and Classification of Ventriculoperitoneal Shunt Valves Utilizing Fine-Tuning of a Detection Model.

O'Connor Zari, Fullenkamp Austin, McBee Morgan P

СтатьяПеревод в очереди

Аннотация

Ventriculoperitoneal (VP) shunts are a mainstay treatment for hydrocephalus and identifying the correct valve type is essential to determine its setting. The proliferation of valve models over the last few decades makes identification on radiographs more difficult and time consuming. We trained a deep learning model to detect and classify VP shunts on radiographs. We curated 2263 skull radiographs spanning 11 valve types and split the data 80/10/10 for training/validation/test. A YOLOv8-large model was fine-tuned with augmentation and hyperparameter search (300 epochs, batch 32, 640 × 640 input). The fine-tuned YOLOv8 model demonstrated robust performance on the test set, achieving a precision (P) of 0.949, recall (R) of 0.930, mean average precision (mAP50) of 0.951, mAP50-90 of 0.755, and max F1 score of 0.952 across all classes at a confidence threshold of 0.524. For individual valve types, mAP50 ranged from 0.841 to 0.995, mAP50-90 from 0.562 to 0.963, P from 0.8 to 1, and R from 0.667 to 1 demonstrating that the model overall performs well but does perform better for some valve types. The fine-tuned YOLOv8 model demonstrates high accuracy and generalization across a range of valve types, suggesting its potential for clinical application. Compared with prior purely classification approaches, detection explicitly localizes each valve, accommodates patients with multiple valves, and enables creation of downstream models to determine valve settings.

Для цитирования: O'Connor Zari, Fullenkamp Austin, McBee Morgan P. Artificial Intelligence Detection and Classification of Ventriculoperitoneal Shunt Valves Utilizing Fine-Tuning of a Detection Model.. Journal of imaging informatics in medicine. 2025. DOI: 10.1007/s10278-025-01794-y.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.