MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/01.ccm.0000218815.46611.63

Медицинская библиотека · Critical care medicine · 2006

Effects of endothelin receptor antagonism on acute lung injury induced by chlorine gas.

Wang Jianpu, Oldner Anders, Winskog Calle, Edston Erik, Walther Sten M

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To test the hypothesis that the endothelin system is involved in chlorine gas-induced lung injury.

DESIGN

Experimental study.

SETTING

Academic research laboratory.

SUBJECTS: Twenty-four domestic juvenile pigs.

INTERVENTIONS: Anesthetized, ventilated pigs were exposed to chlorine gas (400 parts per million in air) for 20 mins and then randomly allocated to four groups (n=6 in each group). The tezosentan pretreatment group received the dual endothelin receptor antagonist tezosentan 20 mins before and hyperoxic gas (Fio2 0.6) after chlorine gas exposure. The tezosentan postinjury treatment group received hyperoxic gas after chlorine gas exposure and tezosentan 60 mins later. Animals in the oxygen group received hyperoxic gas after chlorine gas exposure. Pigs in the fourth group (air) were ventilated with room air (Fio2 0.21) throughout the experiment.

MEASUREMENTS AND MAIN

RESULTS

Hemodynamics, gas exchange, lung mechanics, and plasma endothelin-1 were evaluated for 6 hrs. Chlorine gas exposure induced an increase in circulating endothelin-1 by 90% (p<.05). The acute chlorine gas-induced rise in pulmonary vascular resistance was partly blocked by tezosentan pretreatment (p<.001). Tezosentan postinjury treatment also decreased pulmonary vascular resistance to levels significantly lower than in the air and oxygen groups (p<.001). Recovery of peak airway pressure was better in the tezosentan-treated groups than in the air group. There were significant linear relationships between circulating endothelin-1 and pulmonary vascular resistance (r=.47, p<.001) and endothelin-1 and peak airway pressure (r=.41, p<.001). These relationships were modified by tezosentan.

CONCLUSIONS

Tezosentan modified chlorine gas-induced pulmonary dysfunction, indicating that the endothelin system is involved in this mode of acute lung injury.

Для цитирования: Wang Jianpu, Oldner Anders, Winskog Calle, Edston Erik, Walther Sten M. Effects of endothelin receptor antagonism on acute lung injury induced by chlorine gas.. Critical care medicine. 2006. DOI: 10.1097/01.ccm.0000218815.46611.63.