Mitral valve regurgitation after atrial septal defect repair in adults.
Аннотация
BACKGROUND AND AIM OF THE STUDY: Mitral valve regurgitation (MR) is known to deteriorate following adult atrial septal defect (ASD) repair in the mid to long-term. The study aim was to identify the risk factors for this deterioration.
METHODS
Between 1995 and 2011, a total of 93 consecutive patients (aged > or = 18 years) underwent ASD repair at the authors' institution. Patients who underwent concomitant procedures, other than tricuspid annuloplasty or maze procedure, were excluded; hence, 74 patients were enrolled in the study. MR was evaluated by transthoracic echocardiography shortly after surgery and subsequently on a regular basis in the outpatient clinic. Risk factors for the deterioration of MR were estimated using Cox proportional hazards regression.
RESULTS
The mean patient age at surgery was 48.0 +/- 17.1 years, and 20 patients (27%) had atrial fibrillation (AF) preoperatively. The mean follow up was 6.9 +/- 5.5 years. The degree of MR was not unchanged or not improved in 54 patients (73.0%) (group 1), but was increased by one grade in 12 patients (16.2%) (group 2), and by two or more grades in eight patients (10.8%) (group 3). At surgery, all patients in group 3 were aged > 50 years. In group 3, on echocardiography, the average end-diastolic left ventricular dimension was increased from 41.8 mm to 51.8 mm (p = 0.027), and enlargement of the mitral annulus was noted in seven patients. Four of the group 3 patients required reoperation for MR after ASD repair. The Cox proportional hazards model revealed preoperative AF (p = 0.045, hazard ratio (HR): 11.68, 95% confidence interval (95% CI): 1.05-129.48) and Qp/Qs > or = 2.8 (p = 0.015, HR: 9.19, 95% CI :1.53-55.04) to be independent risk factors of new-onset or aggravated MR (by two or more grades) after ASD repair.
CONCLUSION
An earlier repair of ASD would be preferable in terms of MR aggravated after ASD repair. For elderly patients with a preoperative high Qp/Qs and AF, mitral valve annuloplasty with ASD repair should considered.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.