Clinical presentation of CIED infection following initial implant versus reoperation for generator change or lead addition.

Harper Mariko W, Uslan Daniel Z, Greenspon Arnold J, Baddour Larry M, Carrillo Roger G, Danik Stephan B, Tolosana Jose M, Le Katherine, Miro Jose M, Naber Christoph K, Peacock James, Sohail Muhammad Rizwan, Vikram Holenarasipur R, Prutkin Jordan M

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To explore differences in clinical manifestations and outcomes in those patients who develop infection after undergoing initial implantation versus reoperation.

METHODS

We compared cases of cardiac implantable electronic device (CIED) infection based on initial implantation versus reoperation from 11 centres.

RESULTS

There were 432 patients with CIED infection, 178 occurring after initial device placement and 254 after repeat reoperation. No differences were seen in age, sex or device type. Those with infection after initial implant had a higher Charlson Comorbidity Score (median 3 (IQR 2-6) vs 2 (IQR 1-4), p<0.001), shorter time since last procedure (median 8.9 months (IQR 0.9-33.3) vs 19.5 months (IQR 1.1-62.9), p<0.0001) and fewer leads (2.0±0.6vs 2.5±0.9, p<0.001). Pocket infections were more likely to occur after a reoperation (70.1%vs48.9%, p<0.001) and coagulase negative staphylococci (CoNS) was the most frequently isolated organism in this group (p=0.029). In contrast, initial implant infections were more likely to present with higher white cell count (10.5±5.1 g/dL vs 9.5±5.4 g/dL, p=0.025), metastatic foci of infection (16.9%vs8.7%, p=0.016) and sepsis (30.9%vs19.3%, p=0.006). There were no differences in in-hospital (7.9%vs5.2%, p=0.31) or 6-month mortality (21.9%vs14.0%, p=0.056).

CONCLUSIONS

CIED infections after initial device implant occur earlier, more aggressively, and often due to Staphylococcus aureus. In contrast, CIED infections after reoperation occur later, are due to CoNS, and have more indolent manifestations with primary localisation to the pocket.

Для цитирования: Harper Mariko W, Uslan Daniel Z, Greenspon Arnold J, Baddour Larry M, Carrillo Roger G, Danik Stephan B, Tolosana Jose M, Le Katherine, Miro Jose M, Naber Christoph K, Peacock James, Sohail Muhammad Rizwan, Vikram Holenarasipur R, Prutkin Jordan M. Clinical presentation of CIED infection following initial implant versus reoperation for generator change or lead addition.. Open heart. 2018. DOI: 10.1136/openhrt-2017-000681.