m+Medelevator.RU
← Поиск публикаций
The American journal of cardiology · 2026

DYNAMX Bioadaptor Implantation for Treatment of Complex Coronary Artery Disease: The DYNAMITE Study.

СтатьяНаблюдательное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Leone Pier Pasquale, Mangieri Antonio, Calamita Gianmaria, Regazzoli Damiano, Oliva Angelo, Gitto Mauro, Cozzi Ottavia, Gasparini Gabriele, Stefanini Giulio, Condorelli Gianluigi, Latib Azeem, Reimers Bernhard, Prati Francesco, Colombo Antonio

Аннотация

Percutaneous coronary intervention (PCI) with drug-eluting stent implantation still presents limitations related to permanent vessel caging. Implantation of a novel bioadaptor demonstrated promising outcomes in de novo noncomplex coronary lesions. Our aim was to investigate the performance of the DynamX (Elixir Medical Corporation, Milpitas, CA) sirolimus-eluting bioadaptor in complex coronary lesions. DYNAMITE (DYNAMX stent ImplanTation for the trEatment of complex coronary lesions) is an observational, prospective, single-arm, single-center cohort study that enrolled patients with de novo complex coronary lesions undergoing PCI with DynamX between September 2021 and August 2023. The primary co-endpoints were the difference in mean device area and mean in-device lumen area from postprocedure to 9 months as measured by optical coherence tomography. A total of 55 patients (55 lesions) were enrolled. Mean age was 67 ± 10 years, 7% (n = 4) were female, and 29% (n = 16) were diabetic. Lesions had moderate/severe calcification in 64% (n = 35), were chronic total occlusions in 22% (n = 12), and bifurcations in 16% (n = 9) of cases. Postprocedural mean device area was 8.15 ± 0.64 mm2, and in-device lumen area 8.27±1.78 mm2. At 9-month follow-up, mean device area increased to 8.53 ± 1.71 mm2 (absolute difference: 0.37 ± 0.99 mm²; relative difference: 5.52 ± 14.8%, p = 0.010), and mean in-device lumen area decreased to 7.57 ± 1.86 mm2 (absolute difference: -0.70 ± 1.09 mm²; relative difference: -7.98 ± 14.9%, p <0.001). At 24-month follow-up, 4 patients (7.4%) experienced major adverse cardiac events, including one target vessel myocardial infarction and 4 target lesion revascularization events. In conclusion, DYNAMITE supports the presence of significant positive vessel remodeling in patients with de novo complex coronary lesions after DynamX sirolimus-eluting bioadaptor implantation, and suggests promising device performance at 24-month follow-up.

Предметные рубрики MeSH