Urine samples from disposable diapers: an accurate method for urine cultures.
Аннотация
BACKGROUND
The method of collection of the urine sample is of paramount importance in making a diagnosis of urinary tract infection in infants and children. Squeezing urine out of disposable diapers can provide a urine sample that can be used to detect chemical abnormalities as well as a specimen suitable for microscopic examination. To date there have been no reported studies on the use of this technique for urine culture as compared with samples collected by suprapubic aspiration and catheterization.
METHODS
Urine was obtained from 38 infants aged under 2 years who presented with fever with no obvious cause. All infants had urine collected either by catheterization or suprapubic aspiration and by extraction from a disposable diaper. The urine samples were cultured using standard bacteriologic techniques.
RESULTS
Five infants had a urinary tract infection, as shown by a pure growth of more than 10(5) colonies/mL of a single species of bacterium. In all the cases the same result was obtained from both the diaper urine sample and the sample obtained by suprapubic aspiration or catheter. In 31 infants the urine samples collected by both techniques (diaper and catheter or suprapubic aspiration) were negative, and in only 2 infants did the diaper specimen yield a positive result, while the urine obtained by suprapubic aspiration or catheter was sterile.
CONCLUSIONS
Urine obtained from a disposable diaper can provide a valid sample for diagnosing urinary tract infection. The technique is simple, and can be carried out readily in ambulatory settings with minimal equipment and expense.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.