MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/1071100717709572

Медицинская библиотека · Foot & ankle international · 2017

Anatomic Structures at Risk When Utilizing an Intramedullary Nail for Distal Fibular Fractures: A Cadaveric Study.

Goss David A, Reb Christopher W, Philbin Terrence M

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Retrograde intramedullary fibular nail fixation is being utilized with increasing frequency, particularly in patients at higher risk of wound complications. The purpose of this anatomic study was to assess the relative risk to nearby anatomic structures when implanting a contemporary retrograde locked intramedullary fibular nail.

METHODS

Ten human cadaveric lower extremities were instrumented with a fibular nail. The cadavers were dissected. The shortest distance, in millimeters (mm), between the site of procedural steps and nearby named structures of interest (ie, sural nerve, superficial peroneal nerve, and the peroneal tendons) was measured and recorded. Levels of risk were assigned based on observed distances as high (0 to 5 mm), moderate (5.1-10 mm), and low (greater than 10 mm).

RESULTS

The peroneus brevis (PB) tendon was found to be less than 5.0 mm from the distal skin incision in all specimens. When reaming and inserting the nail through the distal fibula aperture, the PB was less than 5.0 mm in 6 specimens. The peroneus longus tendon was at moderate to high risk when inserting both the proximal and distal syndesmotic screws in 9 specimens. The superficial peroneal nerve was at high risk when inserting an anterior to posterior distal locking screw in 7 specimens. The sural nerve was at low risk for all procedural steps. No structures were violated or damaged during any portion of the fibular nail instrumentation.

CONCLUSION

The peroneal tendons and superficial peroneal nerve were at the highest risk; however, no structures were injured during instrumentation.

CLINICAL RELEVANCE: The current findings indicate that strict adherence to sound percutaneous technique is needed in order to minimize iatrogenic damage to neighboring structures when performing retrograde locked intramedullary fibular nail insertion. This includes making skin-only incisions, blunt dissection down to bone, and maintaining close approximation between tissue protection sleeves and bone at all times.

Для цитирования: Goss David A, Reb Christopher W, Philbin Terrence M. Anatomic Structures at Risk When Utilizing an Intramedullary Nail for Distal Fibular Fractures: A Cadaveric Study.. Foot & ankle international. 2017. DOI: 10.1177/1071100717709572.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.