MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.compmedimag.2026.102786

Медицинская библиотека · Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society · 2026

Self-supervised isotropic reconstruction for abnormality detection in anisotropic MRI.

Hsu Jui-Yo, Lian Pin-Hsun, Chuang Tzu-Yi, Chen Yi-Hwa, Chang Gary Han

СтатьяПеревод в очереди

Аннотация

Accelerating musculoskeletal magnetic resonance imaging (MRI) while preserving diagnostic detail remains challenging because acquiring fully‑isotropic ground‑truth volumes is clinically costly. In routine practice, anisotropic scans with reduced through-plane resolution degrade multiplanar visualization and slice-by-slice review in reformatted planes, obscure subtle abnormalities spanning only a few slices, and limit automated three-dimensional (3D) analyses that assume comparable spatial resolution across axes. We present a two‑stage, fully self‑supervised pipeline that learns directly from anisotropic scans-obviating any paired high‑resolution data-and converts highly anisotropic (8:1) turbo‑spin‑echo volumes into isotropic images and 3D abnormality maps. Unlike prior self-supervised super-resolution methods, Stage 1 uses a single forward multi-view generative adversarial network (GAN) with patch-based contrastive and adversarial objectives rather than a backward/cycle-consistency approach. Stage 2 leverages an anatomy-conditioned denoising-diffusion model for healthy counterfactual generation, yielding voxel-wise lesion maps without external annotations. On 2225 Osteoarthritis Initiative knee scans from five different imaging centres, the framework reduced Fréchet inception distance from 407.4 → 254.4 (coronal) and 429.9 → 266.9 (axial), achieved the best Kernel Inception Distance (KID) / Learned Perceptual Image Patch Similarity (LPIPS) scores among competing unsupervised methods, and was preferred in 65-67% of blinded orthopedist comparisons. Crucially, isotropic enhancement propagated to downstream tasks: femur-tibia segmentation F1 scores increased and previously confluent bone‑marrow lesions were separated into discrete entities, enabling precise volumetric quantification. Robustness experiments demonstrated consistent gains across five imaging centers, synthetic noise/contrast perturbations, and transfer of the resolution-enhancement module to two additional MRI protocols, supporting robustness across sites and acquisition protocols. By eliminating the need for ground‑truth isotropic images while surpassing state‑of‑the‑art unsupervised super‑resolution in both perceptual quality and clinical utility, our method may facilitate retrospective cohort studies and prospective scan-time reduction in heterogeneous knee MRI settings, with preliminary transferability to additional protocols.

Для цитирования: Hsu Jui-Yo, Lian Pin-Hsun, Chuang Tzu-Yi, Chen Yi-Hwa, Chang Gary Han. Self-supervised isotropic reconstruction for abnormality detection in anisotropic MRI.. Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society. 2026. DOI: 10.1016/j.compmedimag.2026.102786.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.