MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/hrt.69.4.347

Медицинская библиотека · British heart journal · 1993

Radiofrequency-assisted balloon dilatation in patients with pulmonary valve atresia and an intact ventricular septum.

Rosenthal E, Qureshi S A, Chan K C, Martin R P, Skehan D J, Jordan S C, Tynan M

Клинический случайСтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To investigate the efficacy and safety of transcatheter radiofrequency-assisted valve dilatation for infants with pulmonary valve atresia and intact ventricular septum as an alternative to the use of laser heated wires.

DESIGN

Prospective clinical study.

SETTING

Three paediatric cardiology centres.

PATIENTS: Four children (aged 5-101 days, weight 2.8 kg) with pulmonary valve atresia and intact ventricular septum underwent percutaneous radiofrequency-assisted valve dilatation.

METHODS

After delineating the atretic valve by angiography, 0.020 inch or 0.018 inch radiofrequency wires were used to perforate the atretic valve. The valve was then dilated with conventional balloon dilatation catheters up to the valve annulus diameter.

RESULTS

In all four cases the radiofrequency wire perforated the atretic pulmonary valve and balloon dilatation was successful. In one patient the radiofrequency wire also passed through the anterior wall of the pulmonary artery causing tamponade which required surgical repair shortly afterwards. This patient died from sepsis six days later. One patient died three weeks after the procedure from septicaemia and a paradoxical coronary embolus. Two patients were discharged after 4 and 14 days respectively.

CONCLUSIONS

Radiofrequency-assisted valve dilatation is a promising alternative to the recently developed laser wire technique. The major advantages are a reduction in cost and improved safety for the staff performing the procedure.

Для цитирования: Rosenthal E, Qureshi S A, Chan K C, Martin R P, Skehan D J, Jordan S C, Tynan M. Radiofrequency-assisted balloon dilatation in patients with pulmonary valve atresia and an intact ventricular septum.. British heart journal. 1993. DOI: 10.1136/hrt.69.4.347.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.