MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1089/sur.2017.087

Медицинская библиотека · Surgical infections · 2017

Antibiotic-Impregnated Central Venous Catheters Do Not Change Antibiotic Resistance Patterns.

Turnbull Isaiah R, Buckman Sara A, Horn Christopher B, Bochicchio Grant V, Mazuski John E

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Antibiotic-impregnated central venous catheters (CVCs) decrease the incidence of infection in high-risk patients. However, use of these catheters carries the hypothetical risk of inducing antibiotic resistance. We hypothesized that routine use of minocycline and rifampin-impregnated catheters (MR-CVC) in a single intensive care unit (ICU) would change the resistance profile for Staphylococcus aureus.

METHODS

We reviewed antibiotic susceptibilities of S. aureus isolates obtained from blood cultures in a large urban teaching hospital from 2002-2015. Resistance patterns were compared before and after implementation of MR-CVC use in the surgical ICU (SICU) in August 2006. We also compared resistance patterns of S. aureus obtained in other ICUs and in non-ICU patients, in whom MR-CVCs were not used.

RESULTS

Data for rifampin, oxacillin, and clindamycin were available for 9,703 cultures; tetracycline resistance data were available for 4,627 cultures. After implementation of MR-CVC use in the SICU, rifampin resistance remained unchanged, with rates the same as in other ICU and non-ICU populations (3%). After six years of use of MR-CVCs in the SICU, the rate of tetracycline resistance was unchanged in all facilities (1%-3%). The use of MR-CVCs was not associated with any change in S. aureus oxacillin-resistance rates in the SICU (66% vs. 60%). However, there was a significant decrease in S. aureus clindamycin resistance (59% vs. 34%; p < 0.05) in SICU patients.

CONCLUSIONS

Routine use of rifampin-minocycline-impregnated CVCs in the SICU was not associated with increased resistance of S. aureus isolates to rifampin or tetracyclines.

Для цитирования: Turnbull Isaiah R, Buckman Sara A, Horn Christopher B, Bochicchio Grant V, Mazuski John E. Antibiotic-Impregnated Central Venous Catheters Do Not Change Antibiotic Resistance Patterns.. Surgical infections. 2017. DOI: 10.1089/sur.2017.087.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.