BACKGROUND

Kpa antigen is a low incidence red blood cell antigen within the Kell system. Anti-Kpa alloantibody may be associated with acute and delayed hemolytic transfusion reactions.

CASE STUDY: We report a case of a clinically significant acute extravascular hemolytic transfusion reaction mediated by previously unrecognized (and undetected) anti-Kpa alloantibody. This reaction occurred in a patient who met all criteria for electronic crossmatch, resulting in the transfusion of an incompatible red cell unit.

RESULTS

Post-transfusion investigation showed the transfused red cell unit was crossmatch compatible at the immediate spin phase but was 3 + incompatible at the antiglobulin phase. No evidence of intravascular hemolysis was observed upon visual comparison of the pre- and post-transfusion peripheral blood plasma. Further testing showed the presence of anti-Kpa antibody. The clinical course of the patient included acute febrile and systemic reaction.

CONCLUSION

Acute extravascular hemolytic transfusion reaction may occur due to undetected anti-Kpa alloantibody. Various strategies for crossmatching are discussed in the context of antibodies to low incidence antigens.

Для цитирования: Padmore Ruth, Berardi Philip, Erickson Kathy, Desjardins Diana, Giulivi Antonio, Tokessy Melanie, Neurath Doris, Saidenberg Elianna. Acute extravascular hemolytic transfusion reaction due to anti-Kpa antibody missed by electronic crossmatch.. Transfusion and apheresis science : official journal of the World Apheresis Association : official journal of the European Society for Haemapheresis. 2014. DOI: 10.1016/j.transci.2014.08.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.