MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jsams.2019.02.004

Медицинская библиотека · Journal of science and medicine in sport · 2019

An assessment of the utility and functionality of wearable head impact sensors in Australian Football.

McIntosh Andrew S, Willmott Catherine, Patton Declan A, Mitra Biswadev, Brennan James H, Dimech-Betancourt Bleydy, Howard Teresa S, Rosenfeld Jeffrey V

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

OBJECTIVES

To assess the utility and functionality of the X-Patch® as a measurement tool to study head impact exposure in Australian Football. Accuracy, precision, reliability and validity were examined.

DESIGNS: Laboratory tests and prospective observational study.

METHODS

Laboratory tests on X-Patch® were undertaken using an instrumented Hybrid III head and neck and linear impactor. Differences between X-Patch® and reference data were analysed. Australian Football players wore the X-Patch® devices and games were video-recorded. Video recordings were analysed qualitatively for head impact events and these were correlated with X-Patch® head acceleration events. Wearability of the X-Patch® was assessed using the Comfort Rating Scale for Wearable Computers.

RESULTS

Laboratory head impacts, performed at multiple impact sites and velocities, identified significant correlations between headform-measured and device-measured kinematic parameters (p<0.05 for all). On average, the X-Patch®-recorded peak linear acceleration (PLA) was 17% greater than the reference PLA, 28% less for peak rotational acceleration (PRA) and 101% greater for the Head Injury Criterion (HIC). For video analysis, 118 head acceleration events (HAE) were included with PLA ≥30g across 53 players. Video recordings of X-Patch®-measured HAEs (PLA ≥30g) determined that 31.4% were direct head impacts, 9.3% were indirect impacts, 44.1% were unknown or unclear and 15.3% were neither direct nor indirect head impacts. The X-Patch® system was deemed wearable by 95-100% of respondents.

CONCLUSIONS

This study reinforces evidence that use of the current X-Patch® devices should be limited to research only and in conjunction with video analysis.

Для цитирования: McIntosh Andrew S, Willmott Catherine, Patton Declan A, Mitra Biswadev, Brennan James H, Dimech-Betancourt Bleydy, Howard Teresa S, Rosenfeld Jeffrey V. An assessment of the utility and functionality of wearable head impact sensors in Australian Football.. Journal of science and medicine in sport. 2019. DOI: 10.1016/j.jsams.2019.02.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.