Baschat Ahmet Alexander, Gungor Sadettin, Glosemeyer Peter, Huber Agnes, Hecher Kurt
Аннотация
OBJECTIVE: To examine effects of fetoscopic laser occlusion of placental vascular anastomoses on umbilical venous volume flow in twin-to-twin transfusion syndrome.
STUDY DESIGN: Absolute umbilical venous volume flow, measured preoperatively and 48 hours after fetoscopic laser occlusion was related to Doppler studies, bladder filling in donors, and anastomoses.
RESULTS: Among 45 patients, recipients had decreased ductus venosus pulsatility index (ductus venosus-pulsatility index for veins, 1.16 vs 1.01; P < .001) and unchanged umbilical venous volume flow after fetoscopic laser occlusion (74.7 vs 74.5 mL; P = .407). Donors had decreased umbilical artery pulsatility (1.34 vs 1.11; P = .008), increased ductus venous-pulsatility index for veins (0.75 vs 0.91; P < .014), and significantly increased umbilical venous volume flow per kilogram by 52.3% (136.6 vs 208.0 mL/Kg/min; P < .001). Donor bladder filling occurred at higher umbilical venous volume flow per kilogram (142.7 vs 221.4 mL/Kg/min; P < .012). Increase in umbilical venous volume flow per kilogram correlated with the net difference in arteriovenous anastomoses (Pearson r = 0.403, P = .006).
CONCLUSION: Fetoscopic laser occlusion in twin-to-twin transfusion syndrome corrects intertwin differences in umbilical venous volume flow by predominant effects in the donor. Reappearance of donor bladder filling correlates with correction of volume flow.
STUDY DESIGN: Absolute umbilical venous volume flow, measured preoperatively and 48 hours after fetoscopic laser occlusion was related to Doppler studies, bladder filling in donors, and anastomoses.
RESULTS: Among 45 patients, recipients had decreased ductus venosus pulsatility index (ductus venosus-pulsatility index for veins, 1.16 vs 1.01; P < .001) and unchanged umbilical venous volume flow after fetoscopic laser occlusion (74.7 vs 74.5 mL; P = .407). Donors had decreased umbilical artery pulsatility (1.34 vs 1.11; P = .008), increased ductus venous-pulsatility index for veins (0.75 vs 0.91; P < .014), and significantly increased umbilical venous volume flow per kilogram by 52.3% (136.6 vs 208.0 mL/Kg/min; P < .001). Donor bladder filling occurred at higher umbilical venous volume flow per kilogram (142.7 vs 221.4 mL/Kg/min; P < .012). Increase in umbilical venous volume flow per kilogram correlated with the net difference in arteriovenous anastomoses (Pearson r = 0.403, P = .006).
CONCLUSION: Fetoscopic laser occlusion in twin-to-twin transfusion syndrome corrects intertwin differences in umbilical venous volume flow by predominant effects in the donor. Reappearance of donor bladder filling correlates with correction of volume flow.