m+Medelevator.RU
← Поиск публикаций
Nature communications · 2025

Wireless battery-free ultrathin lithium-niobate resonator as wearable and implantable electronics for continuous monitoring of mechanical vital signs.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Zhou Lianjie, Liu Pengchuan, Liu Junhan, Yuan Wenlou, Wu Zhongyuan, Xu Dian, Hu Bofan, Shao Yuting, Lu Yifei, Huang Ningge, Li Jiahao, Li Zhongzheng, Liang Fuying, Wu Xiaojun, Ma Lichao, Wang Ming, Di Zengfeng, Li Rui, Bi Yanlong, Xu Fan, Mei Yongfeng, Song Enming

Аннотация

Continuous monitoring of physiological parameters associated with dynamic biomechanics, such as intracranial pressure (ICP) and vital signs, is important for clinical diagnosis of brain diseases and timely medical intervention. Current skin-interfaced and implant technologies face challenges in terms of bulky tethers and/or percutaneous wires with high infection risks. Here, we report the wireless, battery-free, and lightweight devices for both wearable and fully implantable applications. The devices incorporate an ultrathin piezoelectric resonator with suspended lithium niobate thin film (LNTF, 3 μm thick), enabling the wireless tracking of mechanophysiological signals by detecting variations in resonance frequency. We experimentally and computationally establish the operational principles of the resonator sensor and assess the device performance as wearables for dynamically monitoring artery pulse and apnea events during respiration. Implantable wireless pressure sensors adapted from this scheme allow for untethered, minimally invasive ICP sensing with a low detection limit of 0.15 mmHg over a wide range up to 240 mmHg. In vivo experiments performed on rat models validate the device capabilities of accurately capturing clinically relevant ICP variations and elevated levels of ICP under pathophysiological conditions of hydrocephalus, with excellent biocompatibility after long-term implantation periods. These findings create the clinical significance of such battery-less and wireless devices for precise characterization of dynamic biomechanics of living tissues.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты