MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.thromres.2013.07.022

Медицинская библиотека · Thrombosis research · 2013

Comparison of markers of coagulation activation and thrombin generation test in uncomplicated pregnancies.

Joly Berangere, Barbay Virginie, Borg Jeanne-Yvonne, Le Cam-Duchez Veronique

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Pregnancy is a well-established risk factor for venous thromboembolism, and is associated with a state of hypercoagulability or parameters of thrombin generation. Currently, there is a lack of consensual data on thrombin generation during pregnancy. This study aimed to find a sensitive and specific biological marker of coagulation activation and to identify parameters of thrombin generation.

PATIENTS AND

METHODS

The population included 101 women with uncomplicated pregnancies. The objective of this study was to correlate thrombin generation test (measured at 5pM tissue factor, 4μM lipids and without thrombomodulin), with fibrinogen and markers of blood coagulation activation: D-dimer, prothrombin fragments 1+2 (F1+2), thrombin-antithrombin complexes (TAT) and fibrin monomer complexes (FMC) in these women. Internal quality control was performed in each set of experiments.

RESULTS

Fibrinogen, D-dimer, F1+2, and TAT concentrations increased significantly throughout pregnancy, and were correlated with term of pregnancy. In our study, thrombin generation seemed to increase early on, and then remained stable throughout normal pregnancy, in contrast with other markers of blood coagulation activation, excepting FMC. The latter are subject to large inter-individual variations, especially during second trimester. No correlation was demonstrated between thrombin generation parameters and other activation markers.

CONCLUSION

While markers of coagulation activation significantly increased during pregnancy, thrombin generation increased only early on and remains stable during pregnancy. Finding a sensitive and specific biological marker for vascular pregnancy complications, such as FMC and thrombin generation levels, requires further investigation.

Для цитирования: Joly Berangere, Barbay Virginie, Borg Jeanne-Yvonne, Le Cam-Duchez Veronique. Comparison of markers of coagulation activation and thrombin generation test in uncomplicated pregnancies.. Thrombosis research. 2013. DOI: 10.1016/j.thromres.2013.07.022.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.